4.8.1
Gain
The ’Gain’ mode performs a digital, linear amplification with clamping (see Fig. 4.44). It is
configurable in the range from 1.0 to 4.0 (e.g. 1.234).
0
200
400
600
800
1000
1200
0
50
100
150
200
250
300
Grey level transformation − Gain: y = (255/1023)
⋅
a
⋅
x
x: grey level input value (10 bit) [DN]
y: grey level output value (8 bit) [DN]
a = 1.0
a = 2.0
a = 3.0
a = 4.0
Figure 4.44: Applying a linear gain with clamping to an image
4.8 Grey Level Transformation (LUT)