![Photon Focus DR1-D1312(IE)-G2 Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/photon-focus/dr1-d1312-ie-g2/dr1-d1312-ie-g2_user-manual_1553526070.webp)
4 Functionality
DR1-D1312(IE)-200
DR1-D1312(IE)-200
Timing Parameter
Minimum
Maximum
t
d
−
iso
−
input
1
µ
s
1.5
µ
s
t
d
−
RS422
−
input
65 ns
185 ns
t
jitter
0
20 ns
t
trigger
−
delay
0
0.33 s
t
burst
−
trigger
−
delay
0
0.33 s
t
burst
−
period
−
time
depends on camera settings
0.33 s
t
trigger
−
offset
(non burst mode)
80 ns
80 ns
t
trigger
−
offset
(burst mode)
100 ns
100 ns
t
exposure
10
µ
s
0.33 s
t
strobe
−
delay
0
0.33 s
t
strobe
−
offset
(non burst mode)
80 ns
80 ns
t
strobe
−
offset
(burst mode)
100 ns
100 ns
t
strobe
−
duration
200 ns
0.33 s
t
d
−
iso
−
output
150 ns
350 ns
t
trigger
−
pulsewidth
200 ns
n/a
Number of bursts n
1
30000
Table 4.16: Summary of timing parameters relevant in the external trigger mode using camera DR1-
D1312(IE)-200
68
Содержание DR1-D1312(IE)-G2
Страница 2: ......
Страница 4: ...2...
Страница 8: ...CONTENTS 6...
Страница 14: ...2 How to get started GigE G2 Figure 2 3 PFInstaller components choice 12...
Страница 60: ...4 Functionality Figure 4 31 Trigger source Figure 4 32 Trigger Inputs Multiple GigE solution 58...
Страница 96: ...4 Functionality 94...
Страница 122: ...6 Software 120...
Страница 128: ...8 Warranty 126...
Страница 130: ...9 References 128...