background image

8

After  the  trigger  cord  is  properly  connected,  check  the  synchronization  with  a  film
camera.  Adjust the lighting unit to same height as the camera lens and face the lights into
the lens.  The lens aperture should be open to its fullest extent and set on “X” or “zero”
delay.  Remove the camera back.  It is best to perform this test with the modeling lamps
turned off.

While looking at the lens through the back of a film camera, operate the shutter.
A few sheets of white paper in front of the lens will cut down the brilliance of
the flash and aid in making the observation.   The flash of the light should then
appear as a circle the same size as the aperture.  If the circle is flattened on the
sides, or if no light appears through the lens, the shutter is not synchronized.  If
the  shutter  appears  not  to  be  synchronized,  a  reputable  camera  repair  shop
should check the shutter contacts.

The sync polarity is Positive on center pin of cable connectors (Photogenic part
PLTC, and defined in ISO 518.)

Sync  voltage  is  12  vdc  (Spec.  =  less  than  24  vdc  per  ISO  10330:1992E,  and
greater than 9 vdc for Wein photo slave at 10 microampere drain.)  Internal 240
ohm discharge limit, with 68 k ohms continuous limit.

Sync signal = negative pulse, 10 microseconds or longer, from sync voltage to
1.6 vdc or less (per ISO 518.)

PocketWizard

!

 

use:  

The PowerLight built-in receiver is actually 16 channel useable.

The PLUS transmitter is 4 channel.   The PowerLight built-in sync radio receiver will
hunt for a signal for 30 seconds after power is applied.  If a minimum of four consecutive
triggers are seen during that time period, the receiver will assume that channel.   If no
signal is seen, the receiver will operate on whatever channel it was set to before power
was removed.  So, turn on the Plus Transmitter and set the channel to 1, 2, 3 or 4.  Make
sure the local/both/remote switch is set to either both or remote.  Hold the Test button (on
Plus Transmitter) down and turn the PowerLight ON.   Continue to hold the transmitter
Test button down for 6 seconds.  This should be sufficient time to teach the PowerLight
receiver.  When you press the Plus Transmitter Test button subsequently, the PowerLight
will  flash.   Check  transmitter  instructions  for  proper  connection  to  camera  and  other
details.  

To prevent the PowerLight photoslave from triggering the flash, you must

insert a SYNC plug (or _” diameter dowel rod) into the _” sync jack.

Содержание PLR1000DR

Страница 1: ...Sync Constant Color POWERLIGHT Operator s Manual Solair Constant Color PLR500DR Solair Constant Color PLR1000DR Voltage Smart Solair PLRX500DR Voltage Smart Solair PLRX1000DR Remote Studio Control Acc...

Страница 2: ...ervice The Voltage Smart Solair Radio Sync Constant Color models permit use of worldwide voltages and frequencies With these two new Solair Radio Sync Constant Color series optional accessories includ...

Страница 3: ...Do not attempt to use this appliance if it has been dropped or damaged until a qualified service person has serviced it 7 Do not operate the unit with a damaged or broken flashtube or modeling lamp Do...

Страница 4: ...ontrol two of these tabs To mount the reflector squeeze the finger levers towards each other and tilt the reflector past the stationary top tab then past the two tabs that are controlled with the leve...

Страница 5: ...s exceeded A cooling off period of 10 to 45 minutes is required to reset the thermal fuse There is also protection in the microcontroller software which is designed to protect against exceeding the ra...

Страница 6: ...1 10 f stops UP DOWN arrow buttons The watt second settings will be displayed If the adjust button is pressed again the modeling circuit and yellow LED will be turned on Ready Light The Solair Radio...

Страница 7: ...he user returns from another mode Tracking is limited to 6 f stops 3 FULL ON OFF is exactly what it says Press the FULL ON OFF button to turn the modeling lamp OFF LED off or FULL ON LED on Note All c...

Страница 8: ...slave at 10 microampere drain Internal 240 ohm discharge limit with 68 k ohms continuous limit Sync signal negative pulse 10 microseconds or longer from sync voltage to 1 6 vdc or less per ISO 518 Po...

Страница 9: ...ing 2 Either Higher or Lower skips the 0 settings To set or change the Auto Bracketing settings 1 Press the Auto Bracketing button 3 times This will cause the display to read br then H 0 2 Press the s...

Страница 10: ...ight as you obtained previously and at the same color temperature The light produced by the new Solair is constant color No matter what power setting you select the light will be the same color temper...

Страница 11: ...flash power Flash Duration 0 0 5 1 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 Time Intensity t 1 2 Power Duration Total Flash Duration t 1 10 You can see that there is quite a bit of light which would b...

Страница 12: ...xposure or color in this shutter range Most modern films however have increased this range to the point that no adjustments are necessary from approximately 1 second to 1 10 000 second It should be po...

Страница 13: ...st increase the indicated exposure to compensate for long exposure effects use a larger lens opening if possible Extending the exposure time will result in more speed loss contrast change and color sh...

Страница 14: ...8 3 Continuous 11 Minutes 6 116 4 Minutes 4 60 1 2 Continuous 4 Continuous 4 Minutes 2 124 1 4 Minutes 1 85 1 4 Continuous 2 Continuous Exposure Information The following charts give the BCPS output f...

Страница 15: ...el radio receiver Built in Photoslave Push to Test button Synchronization Jack 12 volt isolated Main Supply PLR500DR 105 125 VAC 60 Hz 5 amps Main Supply PLRX500DR 90 250 VAC 50 60Hz 3 5amp Consumptio...

Страница 16: ...ous 7 Minutes 10 40 2 5 Minutes 6 25 1 2 Continuous 8 3 Continuous 4 Minutes 4 60 1 4 Minutes 2 43 1 4 Continuous 4 Continuous Exposure Information The following charts give the BCPS output for variou...

Страница 17: ...receiver Built in Photoslave Push to Test button Synchronization Jack 12 volt isolated Main Supply PLR1000DR 105 125 VAC 60 Hz 5 amp Main Supply PLRX1000DR 90 250 VAC 50 60Hz 3 5amp Consumption PLR100...

Страница 18: ...l the display reads ir then release the button The Digital display should read ir when you press and release the _ UP button again and the display will then read Un 1 or some number 1 to 9 To change t...

Страница 19: ...rnal or in the power cable or outlet at the location Try turning the main power off wait for 5 seconds and turn power back on Er 1 message means that an AC line power voltage problem has occurred This...

Страница 20: ...R 2 infrared receivers and have their unique unit numbers assigned PowerLights may have identical unit number numbers if they are to be operated exactly the same under all studio arrangements Select a...

Страница 21: ...ves will cause interference consult slave manufacturer Trigger cord will not flash unit but charge indicator shows that the system has charged Probable causes 1 Defective trigger cord Defective flasht...

Страница 22: ...chase Modeling lamps are covered for initial use failures only SERVICE The photographer should not attempt to make internal repairs Consult a dealer for an authorized Photogenic Professional Lighting...

Страница 23: ...ector AC power adapter and infrared dome transmitter Used with PLDIR 2 receivers sold separately PLIRC 1 Hand Held infrared transmitter Set and transmit commands to just one light or the entire studio...

Страница 24: ...e PL18R 18 Parabolic for soft illumination and flood lighting 125 degree coverage PL20R 20 Parabolic for portraits feathering flood and fill lighting 65 degree coverage PL24R 24 Parabolic for soft ill...

Отзывы: