19
During the “ir” display if you then press either of the 1/10 buttons you will display “rado”
pressing the 1/10 button again will display a studio “Su” and number 1 through 4. Studio
numbers are assigned with 1/10 buttons. NOTE: the “rado” is currently an internal-only
system and
should not
be used if you intend to use infrared controls. To close “rado”,
press the 1/10 button again until the display reads “ir” then press the _ UP button again.
The next display will be “Un 1” which is your light unit number 1 – 9 assignment. You
must re-set the unit number with the 1/10 adjustment buttons, or the default “Un 1” will
automatically be assigned. Once the unit number has been assigned press the _ up button
which allows the startup sequence to finish and save the new settings.
Diagnostic Display Codes:
Circuits that prevent catastrophic damage to your investment protect the Solair and
Voltage Smart Solair PowerLight units.
“Er-0”
message
means that an AC line power frequency problem has occurred.
This could be internal or in the power cable or outlet at the location. Try
turning the main power off wait for 5 seconds and turn power back on.
“Er-1”
message means that an AC line power voltage problem has occurred.
This could be internal or can happen with voltage spikes and voltage fall-off in
the location power supply. Try turning the main power off wait for 5 seconds
and turn power back on.
“Er-3”
message means over heating has occurred. This could be internal or by
exceeding the recommended flash frequency. (See flash rate chart) Once
“Er-
3”
is displayed a
“COOL”
mode is activated to cool off internal components.
This usually is caused by too many quick-discharges resulting in the
overheating of the unit’s circuits. (See flash rate chart) The unit counts down in
this COOL mode for approximately 4 minutes. This is an electronically timed
period and turning the power OFF will not shorten this period. Therefore, you
must leave the power ON during this COOL-DOWN cycle.
“- - - - “
message means a misfire has occurred. To reset press the test fire
button or turn the power OFF. If the “----“ continues, turn the unit off and have
service performed. Examine the flash tube for damage as this can cause this
misfire message to be illuminated.