Parallel Mono Configuration

The  "Parallel  mode"  ties  the  two  channel  inputs 

together  so  that  both  are  driven  by  the  same 

signal,  without  the  need  for  external  jumpers  or 

wiring.  After  the  inputs,  both  channels  operate 

independently. Though they carry the same signal, 

their  gain  controls  affect  only  their  respective 

channels, which must be used separately. Please 

refer to the previous Rear Panel Description.

 Never 

parallel the speaker outputs.

 

Low-Impedance  and  Distributed  Speakers  on 

Icon Amplifiers

If your application calls for connection of an 8 ohm 

speaker and a distributed line to the same amplifier 

channel,  the  Icon  300  and  Icon  700  are  among 

the very few amplifiers that can do that. However, 

since  most  of  the  audio  power  is  drawn  by  the 

direct-connected  speaker,  you  must  derate  the 

distributed line; and the distributed line should have 

a total power load of no more than one-fourth of the 

amplifiers normal distributed line power rating.

 

Computing maximum allowable distributed 

line  load  with  a  known  low-impedance 

load

MaxTOP  =  [MaxRatedPL  -  ((2  x  MaxRatedPL)/

Impedance)]/2

 

MaxTOP  is  the  sum  of  the  power  taps  of  the 

speakers  connected  to  the  Audio  Transformer 

outputs.

MaxRatedPL is the maximum rated power of the 

amplifier into a two ohm load.

Impedance is the load impedance connected to the 

direct outputs.

Example: One channel of an Icon 700 has an 8-

ohm load connected to the Direct (low impedance) 

output.  Then  the  maximum  power  left  available 

to  drive  a  distributed  line  is:  MaxTOP  =  [550-

((2x550/8)/2)] = 206 Watts

Содержание ICON 300

Страница 1: ...ICON 300 ICON 700 ICON 700 Contractor Power Amplifier English...

Страница 2: ...or when unused for long periods of time 14 Refer all servicing to quali ed service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is...

Страница 3: ...EL DESCRIPTION 6 BALANCE BARRIER STRIP INPUT CONNECTIONS 7 BARRIER STRIP OUTPUT CONNECTIONS 7 AUDIO TRANSFORMER OUTPUTS 8 PARALLEL MONO CONFIGURATION 9 SPECIFICATIONS 10 BLOCK DIAGRAM 11 Phonic reserv...

Страница 4: ...usly Toroidal output transformers provide full electrical isolation and meet worldwide safety agency approval Built in 45 Hz subsonic lter prevents speaker transformer saturation with minimal effect o...

Страница 5: ...situations require the ampli er to be switched off and then back on for normal operating conditions to be restored 3 Clip LED Indicator Icon 300 The LEDs light up at clipping status whenever any cond...

Страница 6: ...n or other ampli er 10 Stereo Parallel Bridge Switch In Stereo operation two separate signals are treated separately by channels 1 and 2 of the ampli ers In Parallel operation one signal is treated by...

Страница 7: ...these levels will produce full rated output power at 8 ohms ICON 300 1 02Volts 2 4dBu ICON 700 1 02Volts 2 4dBu Barrier Strip Output Connections Barrierstripslocatedontherearpanelallowspeaker cable c...

Страница 8: ...mpli er has a power rating of 300W it is always a good idea to make sure the sum of the loudspeaker loads on the distributed line is 240W or less 25 volt line output connection 50 volt line output con...

Страница 9: ...ong the very few ampli ers that can do that However since most of the audio power is drawn by the direct connected speaker you must derate the distributed line and the distributed line should have a t...

Страница 10: ...32dB Input Impedance Balanced Unbalanced 20k 10k ohm Damping Factor 200 direct output S N Ratio Less than 100dB below rated output 20Hz 20kHz Protection Circuits Output offset voitage protection Heat...

Страница 11: ...11 ICON 300 700 CLIP CLIP BLOCK DIAGRAM ICON 300 BLOCK DIAGRAM...

Страница 12: ...12 ICON 300 700 ICON 700 BLOCK DIAGRAM...

Страница 13: ...original date of purchase against defects in material and workman ship under use as instructed by the user s manual Phonic at its option shall repair or replace the defective unit covered by this war...

Страница 14: ......

Отзывы: