Congratulations  on  your  purchase  of  the  Phonic 

Icon 300 or 700 power amplifier. The Icon Series is 

a line of professional power amplifiers specifically 

designed  for  contracting  application.  These  two 

models  each  has  independent  channels  and  is 

available for driving 200V, 140V, 100V, 70V, 50V or 

25V "constant voltage" lines. Each channel has its 

own  power  transformer  (toroidal  type)  secondary 

to  provide  maximum  audio  separation  (minimum 

sound leakage) between two channels, minimizing 

interaction that can otherwise occur on amplifiers 

with a common power supply. 

FEATURES

 

Automatic dual-speed, high efficiency fan 

cooling

 

Rear  panel  detented  gain  controls  for 

security and resetability

 

Stereo,  bridge  or  parallel  operating 

modes

 

XLR and barrier strip inputs

 

XLR  in  and  outs  for  multiple  amplifier 

operation & easy signal pass-through

 

Fully  short-circuit,  temperature  and  DC 

offset protection

 

Barrier strip connection determines output 

mode - 25V, 70V, 100V and direct outputs 

available simultaneously

 

Toroidal  output  transformers  provide  full 

electrical  isolation  and  meet  worldwide 

safety agency approval

 

Built-in  45  Hz  subsonic  filter  prevents 

speaker  transformer  saturation  with 

minimal effect on program material

 

Power-up muting

PRECAUTIONS

1.  When  first  powering  up  the  amp,  keep  the 

amplifier gain controls all the off, in order to 

block potentially damaging or annoying sounds 

caused by defective cables or hookups. When 

turning up the gain, do it gradually, until normal 

operation  is  verified.  These  precautions  are 

necessary  with  all  high-power  amplifiers, 

since they have enough power to blow most 

speakers in abnormal situations.

2.  Check the AV Voltage before connecting the 

AC plug

3.  Speaker  Output  Shock  Hazard!  The  Icon 

300 and 700 amps are capable of producing 

hazardous output voltages. To avoid electrical 

shock, make sure the cover is in place over 

the  output  terminals,  and  do  not  touch  any 

exposed speaker wiring while the amplifier is 

operating.

 

ABOUT THIS MANUAL

Please  be  reminded  that  a  power  amplifier  is  a 

high-current,  high-power  device  and  should  be 

treated  with  respect  and  care.  Please  read  this 

manual before connecting and operating your unit, 

and file it in a safe place for future reference.

 

Содержание ICON 300

Страница 1: ...ICON 300 ICON 700 ICON 700 Contractor Power Amplifier English...

Страница 2: ...or when unused for long periods of time 14 Refer all servicing to quali ed service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is...

Страница 3: ...EL DESCRIPTION 6 BALANCE BARRIER STRIP INPUT CONNECTIONS 7 BARRIER STRIP OUTPUT CONNECTIONS 7 AUDIO TRANSFORMER OUTPUTS 8 PARALLEL MONO CONFIGURATION 9 SPECIFICATIONS 10 BLOCK DIAGRAM 11 Phonic reserv...

Страница 4: ...usly Toroidal output transformers provide full electrical isolation and meet worldwide safety agency approval Built in 45 Hz subsonic lter prevents speaker transformer saturation with minimal effect o...

Страница 5: ...situations require the ampli er to be switched off and then back on for normal operating conditions to be restored 3 Clip LED Indicator Icon 300 The LEDs light up at clipping status whenever any cond...

Страница 6: ...n or other ampli er 10 Stereo Parallel Bridge Switch In Stereo operation two separate signals are treated separately by channels 1 and 2 of the ampli ers In Parallel operation one signal is treated by...

Страница 7: ...these levels will produce full rated output power at 8 ohms ICON 300 1 02Volts 2 4dBu ICON 700 1 02Volts 2 4dBu Barrier Strip Output Connections Barrierstripslocatedontherearpanelallowspeaker cable c...

Страница 8: ...mpli er has a power rating of 300W it is always a good idea to make sure the sum of the loudspeaker loads on the distributed line is 240W or less 25 volt line output connection 50 volt line output con...

Страница 9: ...ong the very few ampli ers that can do that However since most of the audio power is drawn by the direct connected speaker you must derate the distributed line and the distributed line should have a t...

Страница 10: ...32dB Input Impedance Balanced Unbalanced 20k 10k ohm Damping Factor 200 direct output S N Ratio Less than 100dB below rated output 20Hz 20kHz Protection Circuits Output offset voitage protection Heat...

Страница 11: ...11 ICON 300 700 CLIP CLIP BLOCK DIAGRAM ICON 300 BLOCK DIAGRAM...

Страница 12: ...12 ICON 300 700 ICON 700 BLOCK DIAGRAM...