background image

1.  Read  these  instructions  before  operating  this 

apparatus.

2.  Keep these instructions for future reference.

3.  Heed all warnings to ensure safe operation.

4.  Follow all instructions provided in this document.

5.  Do not use this apparatus near water or in locations 

where condensation may occur.

6.  Clean only with dry cloth. Do not use aerosol or liquid 

cleaners. Unplug this apparatus before cleaning.

7.  Do not block any of the ventilation openings. Install 

in accordance with the manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, 

heat registers, stoves, or other apparatus (including 
amplifiers) that produce heat.

9.  Do not defeat the safety purpose of the polarized or 

grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug 
has two blades and a third grounding prong. The wide 
blade or the third prong is provided for your safety. If 
the provided plug does not fit into your outlet, consult 
an electrician for replacement of the obsolete outlet.

10. Protect  the  power  cord  from  being  walked  on  or 

pinched particularly at plug, convenience receptacles, 
and the point where they exit from the apparatus.

11.  Only use attachments/accessories specified by the 

manufacturer.

12. Use  only  with  a  cart,  stand,  tripod,  bracket,  or 

table  specified  by  the  manufacturer,  or  sold  with 
the  apparatus.  When  a  cart  is  used,  use  caution 
when  moving  the  cart/apparatus 
combination to avoid injury from tip-
over.

13. Unplug this apparatus during lighting 

storms  or  when  unused  for  long 
periods of time.

14. Refer  all  servicing  to  qualified  service    personnel. 

Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord or 
plug is damaged, liquid has been spilled or objects 
have  fallen  into  the  apparatus,  the  apparatus  has 
been exposed to rain or moisture, does not operate 
normally, or has been dropped.

IMPORTANT SAFETY INSTRUCTIONS

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

The  lightning  flash  with  arrowhead  symbol,  within  an 
equilateral  triangle,  is  intended  to  alert  the  user  to  the 
presence  of  uninsulated  “dangerous  voltage”  within  the 
product’s enclosure that may be of sufficient 
magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is in-
tended to alert the user to the presence of important operat-
ing and maintenance (servicing) instructions in the literature 
accompanying the appliance.

WARNING: 

To reduce the risk of fire or electric shock, do 

not expose this apparatus to rain or moisture.

CAUTION: 

Use of controls or adjustments or performance 

of  procedures  other  than  those  specified  may  result  in 
hazardous radiation exposure.

The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, 
shall be placed on the apparatus. The MAINS plug is used as the disconnect device, the disconnect device shall 
remain readily operable. 

Warning

: the user shall not place this apparatus in the confined area during the operation so that the mains switch 

can be easily accessible. 

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

Содержание ICON 300

Страница 1: ...ICON 300 ICON 700 ICON 700 Contractor Power Amplifier English...

Страница 2: ...or when unused for long periods of time 14 Refer all servicing to quali ed service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is...

Страница 3: ...EL DESCRIPTION 6 BALANCE BARRIER STRIP INPUT CONNECTIONS 7 BARRIER STRIP OUTPUT CONNECTIONS 7 AUDIO TRANSFORMER OUTPUTS 8 PARALLEL MONO CONFIGURATION 9 SPECIFICATIONS 10 BLOCK DIAGRAM 11 Phonic reserv...

Страница 4: ...usly Toroidal output transformers provide full electrical isolation and meet worldwide safety agency approval Built in 45 Hz subsonic lter prevents speaker transformer saturation with minimal effect o...

Страница 5: ...situations require the ampli er to be switched off and then back on for normal operating conditions to be restored 3 Clip LED Indicator Icon 300 The LEDs light up at clipping status whenever any cond...

Страница 6: ...n or other ampli er 10 Stereo Parallel Bridge Switch In Stereo operation two separate signals are treated separately by channels 1 and 2 of the ampli ers In Parallel operation one signal is treated by...

Страница 7: ...these levels will produce full rated output power at 8 ohms ICON 300 1 02Volts 2 4dBu ICON 700 1 02Volts 2 4dBu Barrier Strip Output Connections Barrierstripslocatedontherearpanelallowspeaker cable c...

Страница 8: ...mpli er has a power rating of 300W it is always a good idea to make sure the sum of the loudspeaker loads on the distributed line is 240W or less 25 volt line output connection 50 volt line output con...

Страница 9: ...ong the very few ampli ers that can do that However since most of the audio power is drawn by the direct connected speaker you must derate the distributed line and the distributed line should have a t...

Страница 10: ...32dB Input Impedance Balanced Unbalanced 20k 10k ohm Damping Factor 200 direct output S N Ratio Less than 100dB below rated output 20Hz 20kHz Protection Circuits Output offset voitage protection Heat...

Страница 11: ...11 ICON 300 700 CLIP CLIP BLOCK DIAGRAM ICON 300 BLOCK DIAGRAM...

Страница 12: ...12 ICON 300 700 ICON 700 BLOCK DIAGRAM...

Страница 13: ...original date of purchase against defects in material and workman ship under use as instructed by the user s manual Phonic at its option shall repair or replace the defective unit covered by this war...

Страница 14: ......

Отзывы: