background image

English     

1.  Read  these  instructions  before  operating  this 

apparatus.

2.  Keep these instructions for future reference.
3.  Heed all warnings to ensure safe operation.
4.  Follow all instructions provided in this document.
5.  Do not use this apparatus near water or in locations 

where condensation may occur.

6.  Clean only with dry cloth. Do not use aerosol or liquid 

cleaners. Unplug this apparatus before cleaning.

7.  Do not block any of the ventilation openings. Install 

in accordance with the manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, 

heat registers, stoves, or other apparatus (including 

.

9.  Do not defeat the safety purpose of the polarized or 

grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug 
has two blades and a third grounding prong. The wide 
blade or the third prong is provided for your safety. If 
the provided plug does not   into your outlet, consult 
an electrician for replacement of the obsolete outlet.

10. Protect  the  power  cord  from  being  walked  on  or 

pinched particularly at plug, convenience receptacles, 
and the point where they exit from the apparatus.

11.  Only use attachments/accessories 

 by the 

manufacturer.

12. Use  only  with  a  cart,  stand,  tripod,  bracket,  or 

table 

  by  the  manufacturer,  or  sold  with 

the  apparatus.  When  a  cart  is  used,  use  caution 
when  moving  the  cart/apparatus 
combination to avoid injury from tip-
over.

13. Unplug this apparatus during lighting 

storms  or  when  unused  for  long 
periods of time.

14. Refer  all  servicing  to 

  service    personnel. 

Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord or 
plug is damaged, liquid has been spilled or objects 
have  fallen  into  the  apparatus,  the  apparatus  has 
been exposed to rain or moisture, does not operate 
normally, or has been dropped.

IMPORTANT SAFETY INSTRUCTIONS

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

The  lightning  flash  with  arrowhead  symbol,  within  an 
equilateral  triangle,  is  intended  to  alert  the  user  to  the 
presence  of  uninsulated  “dangerous  voltage”  within  the 
product’

 

magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is in-
tended to alert the user to the presence of important operat-
ing and maintenance (servicing) instructions in the literature 
accompanying the appliance.

WARNING: 

To reduce the risk of 

 or electric shock, do 

not expose this apparatus to rain or moisture.

CAUTION: 

Use of controls or adjustments or performance 

of  procedures  other  than  those 

  may  result  in 

hazardous radiation exposure.

The apparatus shall not be exposed to dripping or splashing and that no objects 

 with liquids, such as vases, 

shall be placed on the apparatus. The MAINS plug is used as the disconnect device, the disconnect device shall 
remain readily operable. 

Warning

: the user shall not place this apparatus in the 

 area during the operation so that the mains switch 

can be easily accessible. 

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

Содержание AM844D USB

Страница 1: ...AM844D USB User s Manual Manual del Usuario...

Страница 2: ...ENGLISH I ESPA OL II APPENDIX III V1 3 12 24 2014 AM844D USB COMPACT MIXERS MEZCLADORAS COMPACTAS English Espa ol...

Страница 3: ...G CONNECTIONS 2 CONTROLS AND SETTINGS 4 SPECIFICATIONS 8 APPENDIX DIGITAL EFFECT TABLE 1 APPLICATION 2 DIMENSION 3 BLOCK DIAGRAM 4 CONTENTS USER S MANUAL Phonic preserves the right to improve or alter...

Страница 4: ...lighting storms or when unused for long periods of time 14 Refer all servicing to service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or p...

Страница 5: ...MENTS Windows Windows XP SP2 Vista or 7 Intel Pentium 4 processor or better 512 MB RAM 1 GB recommended Macintosh Apple Mac OSX 10 5 or higher G4 processor or better 512 MB RAM 1 GB recommended BASIC...

Страница 6: ...rogram and select the USB Audio Codec in the device preferences 7 Be sure to set your minimum buffer settings to 64 samples as to avoid clicks and pops MAKING CONNECTIONS Channel Inputs 1 XLR Jacks Th...

Страница 7: ...e signal altered by the Control Room level control on the face of the mixer This output has extensive use as it can be used to feed the signal from the mixer to an active monitor for the monitoring of...

Страница 8: ...izers 25 Middle Frequency Control This control is used to provide a peaking style of boost and cut to the level of middle frequency sounds at a range of 15 dB The AM844D USB mixer also provides a swee...

Страница 9: ...effect Each effect s parameter can be found on the digital effect table 36 Effect On Button This button is pushed to turn the corresponding effect panel on or off Effects can also be disabled by using...

Страница 10: ...he rear of the AM844D USB mixer whereas the Phones control adjusts the final signal sent to the Phones A and B jacks on the top of the mixer s face 47 Control Room Phones Source Selection These four b...

Страница 11: ...nal The Group Controls also feature individual left and right buttons which allow you to send the various Group signals to the Main Left and Right This can be handy when wanting to combine the signals...

Страница 12: ...Control Yes Main L R Level Control 60 mm fader Level Meter 13 segment Phantom Power Supply 48V DC Frequency Response Mic input to any output 20Hz 60KHz 0 1 dB 20Hz 100KHz 0 3 dB Crosstalk 1KHz 0dBu 20...

Страница 13: ...sert 10 K ohms RCA 2T Output 1 1 K ohms Equalization 3 band 15dB Low EQ 80Hz Mid EQ 100 8k Hz sweepable L Mid EQ 800 Hz H Mid EQ 3 kHz Hi EQ 12 kHz Low Cut Filter 75 Hz 18 dB oct USB Audio Stereo In O...

Страница 14: ...of the date of purchase You will need it for any warranty service No returns or repairs will be accepted without a proper RMA number return merchandise authorization In order to keep this warranty in...

Страница 15: ...1 1 to 3 8 5 Mid Hall Reverb Time S 0 5 to 1 66 6 Jazz Lounge Reverb Time S 0 15 to 0 9 7 Ping Pong Delay Delay Average S 0 08 to 0 55 8 Short Delay Delay Average S 0 05 to 0 4 9 Vocal Plate Reverb Ti...

Страница 16: ...r instrumentos y dispositivos a las mezcladoras AM Se recomienda que explore las funciones y encuentre la mejor configuraci n posible para sus necesidades que depender de qu instrumentos y cu ntos dis...

Страница 17: ...Appendix Ap ndice 3 AM844D USB DIMENSIONS DIMENSION All measurements are shown in mm inches Todas las medidas est n mostradas en mm pulgadas...

Страница 18: ...FT 3 4 PRE POST MAIN GP RIGHT PHONES PEAK SOLO GAIN AUX SEND AUX SEND3 R MID R L GROUP FADER ON PRE MIX POST MIX PHONES A MIC IN 2 3 1 AUX3 EFX BAL AUX 1 2T RTN R CTRL RM R LINE IN R R RTN3 GP5 L AUX...

Страница 19: ...Appendix Ap ndice 5 AM844D USB MEMO...

Страница 20: ......

Отзывы: