22
7.4
Assembly
After the receipt of the electric cylinder, check the device for any damage. The electric cylinder is delivered ready for operation without a
controller.
The installation of the LD75E+P consists in fixing the electric cylinder using the rear and front suspensions.
The cross bores of both suspensions measure 10.1 0/+0.1 mm according to the standard. The fastening bolts are not included in the
scope of delivery.
The following instructions must be observed during installation:
Stroke end positions are set with the pushrod. The pushrod is not secured against twisting. This means that a turning (rotation) of the
pushrod - or the fixed swivel head - is equal to an adjustment of the end positions!
Attention: The attachment points for installation of the electric cylinder must be aligned flawlessly to ensure the safe and flawless operation!
Action of lateral forces on the pushrod must be excluded!
•
When a swivel head or clevis is used/assembled, the head must be correctly locked using the lock nut supplied.
•
Test or trial run must be performed.
Non-observance of this procedure will cause damage to the electric cylinder!
This nullifies the guarantee!
Installation positions of the components must ensure avoiding pinch and shear points, in particular
taking into consideration any future applications.
Make sure to exclude the tripping hazard by proper and safe laying of the supply lines /
cables!
Содержание LD75E+P
Страница 1: ...EN Assembly Instruction Linear actuator LD75E P 2 B 017 663 Version 1 2...
Страница 11: ...Phoenix Mecano Komponenten AG 11 6 2 Dimensions of geometry...
Страница 15: ...Phoenix Mecano Komponenten AG 15 6 6 1 Assembly disassembly of the connection cable with plug...
Страница 19: ...Phoenix Mecano Komponenten AG 19 6 7 Performance charts Execution1 Execution2 Execution3 Execution4...