FL EPA 2
PHOENIX CONTACT
108452_en_01
5.2
Restoring the factory defaults
The device can be restored to the factory default settings using any of the following
methods:
•
Press and hold the “MODE” button for >10 seconds and then release it.
•
Execute Easy Config Mode 2.
•
Click on “Factory Reset” on the “System Settings” page.
•
Use the “AT&F” command and reboot.
5.3
PROFINET communication
WLAN communication with PROFINET devices requires that “Bridge Mode” is set to “Layer
2 tunnel” on the “WLAN Settings” page in web-based management.
For WLAN and Bluetooth communication with PROFINET devices, it is recommended to
enable the PROFINET optimization. This can either be done using the EasyConfig mode or
manually using an AT command.
Table 5-2
Default settings (default upon delivery)
Network settings
IP assignment
Static
IP address
192.168.0.254
Subnet mask
255.255.255.0
Standard gateway
192.168.0.
254
WLAN settings
Operating mode
Client
Channel
bands
2.4 GHz and 5 GHz
Authentication mode
Open
Channel
Auto
Client operating mode
Layer 2 tunneling
Bluetooth settings
Operating mode
PANU (Client)
Local name
Generated from MAC address
Security mode
Disabled
System settings
Password
-
Setting a secure password for the device is strongly recommended.