Dear Customer,
Congratulations on buying your Phocos product! Please read the instructions carefully and
thoroughly before using the product. Your new CMLup controller is a “state-of-the-art” device
which was developed in accordance with the latest available technical standards. It comes with
a number of outstanding features, such as:
Clear, readable display of the state of charge
New housing design
Acoustic signal when the state of charge changes
Low voltage disconnect regulated by state of charge or voltage
USB connector for mobile phone charging or small music players/devices
Max. 16 mm
2
connector binding posts (10mm² stranded wire with cable end sleves)
Complete electronic protection
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This manual contains important instructions for CMLup controller that shall be followed during
installation, operation and maintenance of the charge controller.
RISKS OF FIRE , USE CONTROLLER WITHIN 0,5 m OF BATTERIES!
Battery type: Lead acid (GEL, AGM, flooded)
Nominal voltage rating of the battery: 12 or 24 V
Battery fuse: Use a fast acting fuse with an interruption rating capacity of 1000 A on the battery
side. We recommend to use a fast acting melting fuse (e. g. car type fuses) as close as possible
to the battery terminal. The maximum current rating should be 1.5 times of the nominal current
of the charge controller.
Please do not disassemble or attempt to repair Phocos products. Phocos charge controllers do
not contain user serviceable parts.
17
EN
Содержание CMLup
Страница 7: ...5 Steckbr cken USB Anschluss DE Sich erung...
Страница 17: ...15 CMLup Sicherer Betriebsbereich Nennlaststrom DE...
Страница 22: ...20 EN USB connector Jumpers...
Страница 32: ...30 EN CMLup Safe Operating Area SOA...
Страница 37: ...35 Puentes Conector USB ES Fusible...
Страница 47: ...45 Corriente consumo nominal ES Area de seguridad SOA del CMLup...
Страница 52: ...50 Cavaliers Port USB FR Fusible...
Страница 63: ...61 Courant nominal charge FR Aire de s curit SOA du CMLup...
Страница 68: ...66 Jumpers Conector USB PO Fus vel...
Страница 79: ...Grau de prote o tipo IP20 Vide gr fico da SOA rea de prote o segura 77 Corrente nominal consumidor PO CMLup SOA...
Страница 81: ...CMLup USB MP3 16 10 CMLup 0 5m GEL AGM 12 24 V 1 5 79 CH...
Страница 82: ...CE CE 12 V 24 V 80 CH...
Страница 83: ...1 2 3 CMLup 10 4 mm2 CMLup 20 6 mm2 CMLup 1 5 CMLup 10 15 A CMLup 20 30 A 81 CH...
Страница 84: ...82 USB CH...
Страница 85: ...12 V 24 V 18 V 24 V 5 LED 83 CH...
Страница 86: ...LED LED 84 CH...
Страница 87: ...75 25 75 25 10 3 LED 2 LED 1 LED 1 LED 25 1 85 CH...
Страница 88: ...LED LED LED CML 1 SOC 11 4 22 8 V 11 9 23 8 V 2 LVD 11 0 22 0 V 1 86 CH...
Страница 89: ...BUZ LVD GEL LED 1 2 3 4 50 V 50 V 15 5 31 0V 1 2 4 6 87 CH...
Страница 90: ...3 4 200 3 s USB USB 5 V 800 mA USB LED LED 88 CH...
Страница 91: ...15 5 31 0 V LED LED LED 89 CH...
Страница 93: ...4 2 mV K per cell 5 mA 40 50 C 4 000 AGM USB 5 0 V 800 mA WXHXD 100 x 100 x 28 mm 130 g 16 mm IP20 91 CH...
Страница 94: ...92 CMLup SOA CH...
Страница 95: ...20140708 Phocos AG Germany www phocos com 93 ISO9001 RoHS CH...