Swimming pool heat pump
- 43 -
Description of the parameters
D——Defrost parameter
D01
——Start defrost temperature
To start the defrost cycle; the condition must be valid for the time d03.
D02
——End defrost temperature
Establishes the temperature above which the defrost cycle ends.
D03
——Defrosting cycle
Represents delay between two successive defrost cycle. The first time, when coil
temperature is lower than D01, there must be valid for the time d03 to start defrost.
D04
——Max.defrosting duration
Represents the maximum duration of the defrost cycle (the defrost ends when the
maximum duration has been arrived, even if the defrost hasn't finished)
34 Heating
stop
differential
r07
0-10
℃
F
35
Minimum set point in Cooling
r08
-30-r09
℃
F
36
Maximum Cooling set point
r09
r08-80
℃
F
37
r
Minimum Heating set point
r10
-30-r11
℃
F
38
Maximum Heating set point
r11
r11-80
℃
F
39
S
On/off switch
S01 CL/OP F/U
40
Water Flow switch
S02 CL/OP F/U
41 System
LP
S03 CL/OP F/U
42 System
HP
S04 CL/OP F/U
43 Mode
switch
S05 CL/OP F/U
44
t
Suction temp.
T01
-30~99
℃
F/U
45
Inlet water temp.
T02
-30~99
℃
F/U
46
Outlet water temp.
T03
-30~99
℃
F/U
47 Coil
temp.
T04
-30~99
℃
F/U
48 Ambient
temp.
T05
-30~99
℃
F/U
49
0
Compressor output
O1 CL/OP F/U
50
Circulate pump output
O2 CL/OP F/U
51
4-way valve output
O3 CL/OP F/U
52
Fan output (High speed)
O4 CL/OP F/U
53
Fan output (Low speed)
O5 CL/OP F/U
54
Electronic expansion valve output
O6 0~500 F/U
Содержание PASRW015
Страница 14: ...Swimming pool heat pump 13 Dimension Model PASRW015 Model PASRW020 030 040...
Страница 15: ...Swimming pool heat pump 14 Model PASRW050S 060S...
Страница 21: ...Swimming pool heat pump 20 13 Hydraulic system Installation sketch map...
Страница 25: ...Swimming pool heat pump 24 Model PASRW040 P Model PASRW050 060S U P...
Страница 29: ...Swimming pool heat pump 28 System diagrams...
Страница 49: ...Swimming pool heat pump 48...
Страница 52: ...Swimming pool heat pump 51 PHNIX Guang Dong PHNIX eco energy solution Ltd...