Important Safety Notice
The battery presents a risk of electrical shock and a high short circuit current. The
Signify mounting instructions must be strictly followed, otherwise potential application,
reliability, or safety issues may arise. Contact your local Signify service if the
instructions cannot meet special field conditions.
Only a qualified Sig nify service representative who is knowledgeable in batteries and
the required precautions is permitted to service the battery. Keep unauthorized
personnel away from batteries.
Danger:
1. The battery package maybe explode by shock, please be careful during handling.
2. When moving batteries. Wear all appropriate safety clothing and equipment.
3. Prohibit dispose of the batteries in a fire. The batteries could explode.
Caution:
1. The misuse of this equipment could result in human injury and/or equipment damage.
In no event will S i g n i f y be responsible or liable for either indirect or consequential
damage or injury that may have resulted from the misuse of this equipment.
2. Use tools with insulated handles to avoid inadvertent shorts.
3. Verify circuit polarities before connecting.
4. Connect sequence: a) connect
load
,; b) connect
battery
; c) connect
charging
source (PV)
.
5. Disconnect sequence: a) disconnect
charging source (PV)
; b) disconnect
battery
;
c) disconnect
load
.
Warning:
1. Failure to replace a battery before it becomes exhausted may cause the case to
crack, possibly releasing electrolytes from battery and resulting in secondary issues
such as odor, smoke, and fire.
2. The battery system must be in proper maintenance according to the "
Maintenance
"
manual in this book. This is essential for safety and the reliability of the lighting system.
3. Do not dispose of batteries except through channels in accordance with local, state
and federal regulations.
4. Positive and negative connectors of PV panel and battery are properly connected
with charge controller.
Don
’t connect the battery positive to PV panel positive and
vice versa.
Notice: The mounting instructions in this document is for standard solar lighting system
installation. It is vitally important that you observe the precautions recommended in this
manual.