Philips UrbanSpark Скачать руководство пользователя страница 12

Maintenance

Panel :-

1. Normally you don't need to clean the panel frequently, it depends on the local 
environment.
2. In heavy dust area, it is required to clean the solar module regularly with a damp towel to 
guarantee optimum performance of the solar panel.
3. Do not use any type of solvent for cleaning and be careful not to put too much pressure 
on the module while cleaning.
4. You Should clean small ads regular.
5. You should trim the trees and branches which cover the PV panel regular.

Battery:-

Battery normally does not need any maintenance within the warranty. If any abnormal 
symptom or special requirement, following tests can be taken: -
1. Check whether there is some loose connection.
2. Measure and record ambient temperature in the pole.
3. Check the battery if it has deformation.

Battery Storage:-

The battery should be stored in clean and dry environment.
Storage time: battery is ex-work in fully charged, storage time should be limited. For 
ensuring battery performance, do not exceed storage time as following definition: 

Under -20

~25

, six months.

Under -20

~35

, three months.

Under -20

~45

, one month.

Warning

1. The recycle of the used battery should strictly follow the local laws and regulations. It is 
forbidden to handle the battery as normal garbage for disposal.
2. Do not open, short circuit, or mutilate batteries as injury may occur.
3. Do not put the battery into a pool.
4. Never move battery by pulling the cables of the battery.
5. The installation is highly suggested during the day. 
6. Only be charged with authorized charger by Signify.
7. Handle the panel pole and battery with great care during the installation and 
transportation.
8. Always

 

keep sparks, flames and smoking materials away from the battery.

9. In case of fire: To extinguish a fire of a battery, use CO2, foam, or dry chemical 
extinguishing media. 

Do NOT 

discharge the extinguisher directly onto the battery. The 

resulting thermal shock may cause cracking of the battery case/cover.

Important

If you have any question concerning safety when working with the battery operated solar 
system, contact your local Signify sales/service representative.

Maintenance

12

Содержание UrbanSpark

Страница 1: ...UrbanSpark Mounting Instructions V3 1 1 ...

Страница 2: ...e resulted from the misuse of this equipment 2 Use tools with insulated handles to avoid inadvertent shorts 3 Verify circuit polarities before connecting 4 Connect sequence a connect load b connect battery c connect charging source PV 5 Disconnect sequence a disconnect charging source PV b disconnect battery c disconnect load Warning 1 Failure to replace a battery before it becomes exhausted may c...

Страница 3: ...can not avoid the shade you must ensure the shade below the 2m of the pole If you do want to install the system at a shade area please consult to Signify professional people 2m 2m unit mm M20 nuts Advise material SUS Spring Washers Advise material SUS Spring Washers Advise material SUS All the pictures in the MI sheet are representative only and may vary from the actual product 235 235 60 M 20 nut...

Страница 4: ...ry Luminaire Cross screwdriver Spanner Max open size 30mm Multimeter optional T30 6 Lobe pin drive key Part of supply Steel rope Φ1 5Mm length 8m Note Luminaire may be different according to different requirements OR All the pictures in the MI sheet are representative only and may vary from the actual product M8 Socket screw wrench Size 5 4 ...

Страница 5: ...0 400 250 Hard Block Soft cushioning M10 Screw M10 Washers 2x M10 Nut M10 Lock Nut M10 Screw M10 Washers 2x M10 Nut M10 Lock Nut 3 Open the service hatch door using the T30 6 Lobe pin drive key provided along with the PV Cartridge 5 4m Pole Assembly 1 Insert the PV cartridge to the pole as shown Pass the cartridge cable through the cutout provided and then pull the same using steel rope from servi...

Страница 6: ...embly OR 1 Insert the PV cartridge bottom first and pass the cable through the cutout given and then pull the same using steel rope from service hatch 3 Unscrew M8 screws and open top cover from PV Cartridge Top 8 N m 5mm 5mm torque 8 N m 5mm 5mm torque 8 N m 5mm torque Wa rni ng Wire should be pulled out properly don t let the wire to come between mating faces 2 Fix the PV Cartridge bottom using ...

Страница 7: ...driver 7b Then affix back the rubber covers X8 and rubber caps X4 8 Connect male and female MC4 T2 connectors to both PV Cartridge cables through service hatch PV Cartridge Top PV Cartridge Bottom MC4 connector T2 Male MC4 connector T2 Female 2 5 N m P1 torque 2 5 N m P1 torque 4 Connect both MC4 connectors of PV cartridge top cable to the 4m long MC4 extension cable then Insert the PV cartridge t...

Страница 8: ... the pictures in the MI sheet are representative only and may vary from the actual product Affix the pole by M20 Nuts spring washers and flat washers Affix the pole For both 4m and 6m 8 6 Luminaire Assembly for both 4m and 6m Pull the luminaire cable using steel rope from service hatch and tighten screws to affix the luminaire Note Refer luminaire mounting instruction sheet for luminaire fixing gu...

Страница 9: ... Note 1 Configure the charge controller as per customer requirement For more details contact Signify Local sales Service representative 2 Positive and negative connectors of PV panel and battery are properly connected with charge controller Don t connect the battery positive to PV panel positive and vice versa Indicators LED Blinking 1 Sec ON off Green Orange As per design Normal Charging LED Blin...

Страница 10: ...ation dimensions follow the MI yes No 4 Products If all components no damaged yes No 5 Bolts If four bolts are fixed yes No 6 Wiring If the wiring is done as per the instruction yes No 7 Fixing of PV Cartridge with Pole If all the screws are are properly tightened and rubber bolt cover are placed over yes No 8 Work status If the work status comply to the request yes No 9 Luminaire If the luminaire...

Страница 11: ... incorrect Reconfigure the charge controller Battery capacity is low Wait for several sun days for recovering battery or recharge the battery by charger Luminaire power is high Reconfigure the charge controller Part or all PV panel disconnection Connect all PV panel Dimming mode Reconfigure the charge controller RTE work mode enable Reconfigure the charge controller Power less than specifications ...

Страница 12: ...ry performance do not exceed storage time as following definition Under 20 25 six months Under 20 35 three months Under 20 45 one month Warning 1 The recycle of the used battery should strictly follow the local laws and regulations It is forbidden to handle the battery as normal garbage for disposal 2 Do not open short circuit or mutilate batteries as injury may occur 3 Do not put the battery into...

Страница 13: ...e the charge controller as per customer requirement For more details contact Signify Local sales Service representative 2 Positive and negative connectors of PV panel and battery are properly connected with charge controller Don t connect the battery positive to PV panel positive and vice versa Indicators LED Blinking 1 Sec ON off Green Orange As per design Normal Charging LED Blinking 0 5 Sec ON ...

Отзывы: