SL NITRO 510 LED STROBE Luminaire Main Menu Options
19
SL NITRO 510 LED STROBE Luminaire
Installation & User’s Manual
Sh wline
Anytime the fixture is locked, each PIN code will unlock all functions except the pertaining features assigned via the
security level.
Note:
The Level 3 PIN will always unlock all functions.
Use the Up and Down buttons to select security PIN codes. Press the Check button and then use Left and Right and
Up Down buttons to assign the pin code. Press the Check button to save the new PIN code.
The Power-Up Level parameter assigns a lock level to the fixture when power is applied. Use the Up and Down
buttons to select the Power-Up Level, and then use the Left and Right buttons to select the Power-up Level option.
Settings/General
Use the Up and Down buttons to select parameters and the Left and Right buttons to assign the different general
fixture settings. When finished, press the Check button to exit the menu level. The adjustable parameters are
described in Table 6.
Settings/Factory Default
Factory default menu settings can be recalled through this menu option. You can select if you wish to overwrite the
user edited preset and chases.
Use the Up and Down buttons to select parameters and the Left and Right buttons to assign the different settings.
When finished, press the Check button to exit the menu level. The adjustable parameters are described in Table 7.
Table 4: Security Lock Levels
Lock Level
Menu Functions Affected
Level 1
Edit Presets, Edit Chases, and Settings Menu
Level 2
Settings Menu
Level 3
All
Table 5: PIN Level Parameters
Parameter
Description
Enter Pass PIN
Enter a PIN code matching the level codes assigned in the Settings/Security menu to
toggle the current security level.
Level 1 PIN
Edit the PIN code used to toggle the Level 1 security.
Level 2 PIN
Edit the PIN code used to toggle the Level 2 security.
Level 3 PIN
Edit the PIN code used to toggle the Level 3 security.
Power-up Level
Select the security level to default to when the fixture is powered ON.
•
Disable PIN will disable all security functions.
•
Locked will lock all functions.
Table 6: General Level Parameters
Parameter
Description
Power-Up
Select the action of the fixture when the unit is powered ON. You can select from Off, Last
Set, presets, and chases.
Mode
Select either Master/Slave (see
Master / Slave Operational Mode
for more information).
Dimming Curve
Select one of four dimming curve choices (see
Dimming Curve Selection
for more
information).
Fan Control
Select Auto of Off fan operation (see
DMX CONTROL
for more information).
Table 7: Factory Default Parameters
Parameter
Description
Protected
•
No - all menu items are able to be restored to factory defaults.
•
Preset & Chase - user edited Presets and Chases are not able to be restored to fac-
tory defaults.