Installation & User’s Manual
SL BAR 620 RGBW LED Luminaire
1 6
OPERATION AND PROGRAMMING
Sh wline
Settings/General
Use the Up and Down buttons to select parameters and the Left and Right buttons to assign the different general
fixture settings. When finished, press the Check button to exit the menu level. The adjustable parameters are
described in Table 9.
Settings/Factory Default
Factory default menu settings can be recalled through this menu option. You can select if you wish to overwrite the
user edited preset and chases.
Use the Up and Down buttons to select parameters and the Left and Right buttons to assign the different settings.
When finished, press the Check button to exit the menu level. The adjustable parameters are described in Table 10.
Settings/DMX
DMX configuration options are available in the DMX menu.
Use the Up and Down buttons to select parameters and the Left and Right buttons to assign the fixture's DMX
settings. When finished, press the Check button to exit the menu level. The adjustable parameters are described in
Table 11.
Table 9: General Level Parameters
Parameter
Description
Power-Up
Select the action of the fixture when the unit is powered ON. You can select from Off, Last
Set, Color filters, presets, and chases.
Mode
Select either Master/Slave (see
Master / Slave Operational Mode
for more information).
Dim Response
Select Normal, Incandescent, or Reduced dimming response.
•
Normal: Fixture LEDs dim with a normal response.
•
Incandescent: Fixture LED’s dim with an incandescent emulation response. The
response to dimming commands will be slightly delayed at lower intensities.
•
Reduced: The response to dimming commands will be calculated with a smaller algo-
rithm to provide emulation with other manufacturer's products.
Dimming Curve
Select one of four dimming curve choices (see
Dimming Curve Selection
for more
information).
Calibration
Toggle Harmonize Color Calibration on or off (see
Harmonize Color Calibration
for more
information).
Fan Control
Select Auto of Off fan operation (see
DMX CONTROL
for more information).
Table 10: Factory Default Parameters
Parameter
Description
Protected
•
No - all menu items are able to be restored to factory defaults.
•
Preset & Chase - user edited Presets and Chases are not able to be restored to fac-
tory defaults.
Load Factory
•
No - no action.
•
Yes - restore to factory default menu settings.
Table 11: DMX Setting Parameters
Parameter
Description
DMX Enable
•
Enable - Fixture will respond to DMX commands/signals.
•
Disable - Fixture will ignore DMX commands/signals.
Address
Assigns the fixture’s DMX start address.
Map
Selects the DMX map for the fixture to use (see
DMX CONTROL
section for more
information).
When no DMX
Selects the action of the fixture when the unit is powered ON and not receiving DMX.
•
Off - Turn off all LED output.
•
Last Action - restore the last menu action.
•
Power-up - follow the power-up value in the settings menu.
•
Hold - continue with the last DMX values received.
LED Group
Select the number of LED groups to control via DMX (see
DMX CONTROL
section for
more information)