Installation & User’s Manual
SL BAR 620 RGBW LED Luminaire
8
INSTALLATION AND SET UP
Sh wline
2. Connecting Power
Units can be powered in one of two ways:
• Direct connection to a AC power source using an AC input cable. For wiring of AC input connector, refer to
"Con-
necting SL BAR 620 RGBW LED Luminaires to AC Power"
below.
• Connection from the AC output of another SL BAR 620 RGBW LED Luminaire. When using this method, it is
very important not to connect any other type of equipment device.
WARNING!
Only connect other SL BAR 620 RGBW LED Luminaires to the AC Output (Thru) connector of a SL
BAR 620 RGBW LED Luminaire.
Connecting SL BAR 620 RGBW LED Luminaires to AC Power
If the unit is supplied with an AC input cable without an input connector installed. The input connector is a user-
supplied accessory.
Table 2 on page 8 describes how to connect power to your SL BAR 620 RGBW LED Luminaire. Field wiring of the
SL BAR 620 RGBW LED Luminaire is straight forward. The following wiring scheme is used:
Table 2:
SL BAR 620 RGBW LED Luminaire (IP20 Rated Models) AC Input Connections
Figure 4: SL BAR 620 RGBW LED Luminaire AC Input & Output Connections
Wire Color
Purpose
Brown
Main / Line (100 to 240VAC)
Blue
Neutral
Green/Yellow
Ground (Earth)
Back of Unit
AC Input
AC Output
Neutral
Main /
Ground / Earth
Line
AC Connector
(on side of unit)
AC Input Connector (on Unit)
Neutral
Main /
Ground / Earth
Line
AC Connector
(on side of unit)