SL BAR 620 RGBW LED Luminaire Main Menu Options
15
SL BAR 620 RGBW LED Luminaire
Installation & User’s Manual
Sh wline
Settings/Security
All Showline fixtures have a multiple level locking feature. This allows you to configure the fixture and allow
different menu access to multiple users. The menu system can be locked instantly or assigned to power on to a
particular lock level. You can assign three different 4-digit PIN (personal identification number) codes to each unlock
specific levels of functionality within the menu system.
Anytime the fixture is locked, each PIN code will unlock all functions except the pertaining features assigned via the
security level.
Note:
The Level 3 PIN will always unlock all functions.
Use the Up and Down buttons to select security PIN codes. Press the Check button and then use Left and Right and
Up Down buttons to assign the pin code. Press the Check button to save the new PIN code.
The Power-Up Level parameter assigns a lock level to the fixture when power is applied. Use the Up and Down
buttons to select the Power-Up Level, and then use the Left and Right buttons to select the Power-up Level option.
Table 6: Strobe / Timing Parameters
Parameter
Description
Master Intensity
Overall fixture output intensity level.
Strobe: X
Strobe mode and rate value settings following DMX map (see
DMX CONTROL
for
details).
Duration
The time each strobe flash remains ON.
Intensity Timing
The time used to change intensity values when running a chase.
Color Timing
The time used to change color values when running a chase.
Table 7: Security Lock Levels
Lock Level
Menu Functions Affected
Level 1
Edit Presets, Edit Chases, and Settings Menu
Level 2
Settings Menu
Level 3
All
Table 8: PIN Level Parameters
Parameter
Description
Enter Pass PIN
Enter a PIN code matching the level codes assigned in the Settings/Security menu to
toggle the current security level.
Level 1 PIN
Edit the PIN code used to toggle the Level 1 security.
Level 2 PIN
Edit the PIN code used to toggle the Level 2 security.
Level 3 PIN
Edit the PIN code used to toggle the Level 3 security.
Power-up Level
Select the security level to default to when the fixture is powered ON.
•
Disable PIN will disable all security functions.
•
Locked will lock all functions.