SCF870/20 /21 /22 /23
4-9
DISASSEMBLY- AND RE-ASSEMBLY ADVISE
DISASSEMBLY
1st operation:
- Detach the water cap by pulling it towards the side and, unscrew 1 piece of 3,5 x 13 special safety screw and 3 pieces of
3,5 x 13 screw.
2nd operation: Detaching the cables from terminal block
- Remove the bottom lid and unscrew the screws of terminal block to remove brown and black cables which are attached to rotary
switch.
3rd operation: Detaching the internal cables and thermostat cables
- Remove the thermostat cable and other internal cables.
- Pull the female terminals by gripping them at the cable-end side.
ATTENTION: Female terminals can be deformed during disassembly and get loose. If these terminals are reused, there will be
risk for self detaching, electric arc occurance, and/or malfunction. Additionally, when the female terminals are gripped over the
sleeves, this may damage or rip the sleeves. Heat sleeves should be removed before detaching the terminals.
- Unscrew the M3 nut to remove the thermofuse holder.