Technical Specification and Connection Facilities
1-7
4.1.3
Mains Drop-out Immunity
The product shall withstand mains failures of:
Variation 0% (=100% dip) at T-event = 50 mSec. Performance criterion B
Variation 40% (=60% dip) at T-event = 100 mSec. Performance criterion B
Variation 0% (=100% dip) at T-event = 5 Sec. Performance criterion C
Additional for USA apparatus: See 3135 019 8029 Reliability evaluation.
Variation 0% (=100% dip) at T-event = 100 mSec in standby mode. Performance criterion B
Requirement:
No misoperation and no interference of user in order to guarantee continuation of performed function.
Reference: IEC61000-4-11 For measuring method refer to UAN-D1724, as far as applicable.
Performance criterions according to IEC61000-4-4 Amendment 1
Performance Requirement
Criterion A - No any degradation of specification.
Criterion B - Temporary degradation / self recoverable.
Criterion C - No damage, resolvable hang-up.
Criterion D - Not recoverable loss of function.
4.1.4
Power Consumption
Power consumption at nominal AC input:
1. CD play mode at 1/8 P-rated output power MCM7000:
40
W
2. Low Power Standby Mode
:
0.5
W
Содержание MCM7000/12
Страница 30: ...AMP BOARD Layout Diagram 12 2 12 2 ...
Страница 32: ...Display Board Layout Diagram 12 4 12 4 ...
Страница 35: ...Key Board Layout Diagram 12 7 12 7 ...
Страница 38: ...T5AH 250V Power Board Layout Diagram 12 10 12 10 ...
Страница 42: ...Decoder Board Layout Diagram 12 14 12 14 ...
Страница 44: ...Revision List Revision List Version 1 0 Initial Release 14 1 ...