Chapter 10: UART1
10.3.17 UART1
Transmit
Enable
Register (U1TER - 0xE001 0030)
LPC2101/02/03’s U1TER enables implementation of software and hardware flow control.
When TXEn=1, UART1 transmitter will keep sending data as long as they are available.
As soon as TXEn becomes 0, UART1 transmission will stop.
describes how to use TXEn bit in order to achieve software flow control.
a. Mode 0 (start bit and LSB are used for auto-baud)
b. Mode 1 (only start bit is used for auto-baud)
Fig 21. Autobaud a) mode 0 and b) mode 1 waveform
UART1 RX
start bit
LSB of 'A' or 'a'
U1ACR start
rate counter
start
bit0
bit1
bit2
bit3
bit4
bit5
bit6
bit7
parity stop
'A' (0x41) or 'a' (0x61)
16 cycles
16 cycles
16xbaud_rate
UART1 RX
start bit
LSB of 'A' or 'a'
rate counter
'A' (0x41) or 'a' (0x61)
start
bit0
bit1
bit2
bit3
bit4
bit5
bit6
bit7
parity stop
U1ACR start
16 cycles