EXPLODED VIEW

Содержание HD7853/60

Страница 1: ... as officially laid down at this moment TECHNICAL INFORMATION Voltage 220 240V Frequency 50 60 Hz Power consumption 2650 W Boiler 1450 W Steam heater 1200 W Standby power switched off 1 W Standby power 30 W switched on 30 min room temperature Pressure Coffee system 1 6Bar Pressure Steam system 1 Bar Contents water reservoir 1200 cc mL Contents milk reservoir 120 cc mL Auto shut off 30 min Colour s...

Страница 2: ...e Brew Chamber g h e d f aa j c b o kk i a Legend Low pressure tube High pressure tube Low pressure connections High pressure connections a p aa ll CONTROL PCB CONNECTION PCB L N Boiler Pump M Steam pump M Fuse Push buttons Temp sensor boiler Water level sensor Descale tool detector Milk tank detection sensor Fuse Thermo block Fuse Fuse Temp sensor Thermo block Lid close detection switch TCO Y W X...

Страница 3: ...ap lock which is holding the micro switch assembly see picture for detail Gently pull out the switch assembly Reassemble follow above steps backwards Remove brew chamber cover to reach user interface PCB To remove the brew chamber lid cover place the screwdriver on the positions see picture and lift the cover over the snap locks on both positions The cover lid can now be lifted a little Remove the...

Страница 4: ...ppliance on and wait until the unit is ready to brew 3 Choose the setting of which you want to adjust the volume 4 Be sure a pod holder is placed but without a Coffee POD Only adjusting with plain water 5 Place a cup on the drip tray cover Press the 1 cup button once to measure the black coffee volume press the 1 cup button twice to measure the coffee volume in a cappuccino 6 When the appliance ha...

Страница 5: ...sful the software will clear a Boiler_empty_flag in the Eeprom By means of this Boiler_empty_flag the system knows the boiler is filled or not When the Senseo is switched off or disconnected from the mains the value of the Boiler_empty_flag is stored in the Eeprom chip Restoring the Boiler_empty_flag to production default Some times it is needed that the boiler of the Senseo have to be emptied Thi...

Страница 6: ... 42440 4222 259 49363 4222 259 50892 4213 247 05250 Sensor decalcification assy Steam connecting assy Spouthousing Sensor milk container Foot Deep Black 26 27 28 29 30 4222 259 42430 4222 259 41230 4222 247 58780 4222 259 50831 4222 259 41502 Lid switch lid close detection assy Steam pump Valve outlet 3 WayValve assy Backcover assy CEME E151 Deep Black Deep Black 31 32 33 34 35 4222 247 05510 4222...

Страница 7: ...HD7853 60 61 62 7 11 2 5 6 7 3 1 9 8 4 EXPLODEDVIEW ...

Страница 8: ...HD7853 60 61 62 8 11 g h 11 10 12 13 14 15 EXPLODEDVIEW ...

Страница 9: ...HD7853 60 61 62 9 11 gg c i a b i j ll ff g p f e aa U T V S X 18 17 22 20 21 23 19 16 29 30 33 25 24 27 26 45 28 34 32 31 32 EXPLODEDVIEW ...

Страница 10: ...HD7853 60 61 62 10 11 c d e Y X W W V U T S 41 40 42 43 44 45 y 39 35 38 37 36 EXPLODEDVIEW ...

Страница 11: ...HD7853 60 61 62 11 11 bb cc dd k p l m n ee o gg ll hh kk jj ii aa ff 49 48 46 46 47 EXPLODEDVIEW ...