HD6553/10
2-10
Technical information
General coff ee specifi cations:
In-cup volume (mL) Coff ee
1-cup (ml)
1-cup Strength select (ml)
General version
122
60
French, Spanish version
100
60
Temperature indication (°C)
1
st
cup temperature
2
nd
and further cup temperature
General version (122 ml)
> 74 °C
> 76 °C
French, Spanish version (100 ml)
> 69 °C
> 73 °C
Water specifi cation in (mL)
(without coff ee pod)
1-cup (ml)
(with 1-cup pod holder)
2-cup (ml)
(with 1-cup pod holder)
General version (normal cup 122 ml)
133 ± 10
266 ± 10
French, Spanish version (normal cup 100 ml)
109 ± 20
218 ± 20
All countries (short cup 60 ml)
71 ± 10
142 ± 10
Diff erence between left/right volume:
< 10ml
< 10ml
Functional diagram
Boiler
Pump
3-way valve
Brew
head
Water
Container
Electical diagram
CONTROL
PCB
L
N
Boiler
Pump M
Push buttons
TCO
Fuse
Fuse
Temp.
Sensor
Water level
Sensor