Repair instruction
The new PCBA has an extra feature onboard “Intensity select”, which need to be enabled for the following type numbers
(HD6554, HD6555 & HD6556).
Intensity select how does that work:
•
Select the strong short coffee recipe by double tap on the 1-cups button for 1 cup of strong short coffee.
•
Press the 1-cup button once for one large mild cup of coffee.
•
Select the strong short coffee recipe by double tap on the 2-cups button for a double cup of strong short coffee.
•
Press the 2-cup button once for two large mild cups of coffee.
Selecting the right PCBA modus.
Enable/Disable the “Intensity select” feature.
The PCBA is standard delivered with the “Intensity select” feature
disabled
, this for easy servicing the existing SENSEO®
Original HD78xx & HD6553 range with OPR Boiler installed.
The “Intensity select” function can be simple enabled/disabled:
1. Hold the 2-cups button while applying power to the appliance.
2. Release the 2-cups button.
3. Press the 1-cups button to confi rm the action of changing the “Intensity select” functionality.
4. Release the 1-cup button.
Once changed, please check functionality by making a coff ee and double press the 1-cup coff ee button, the volume of the
coff ee should be ± 60ml. (water 61 – 81 ml)
To change back the “Intensity select” function again, simply repeat steps 1 to 4.
2x