Parts list

Pos

Service code

Description

Remark

1

4222 259 67811

Brew chamber assy  Coff ee boost

Star white

2

4222 259 62781

Pad holder assy 1-cup

Black

3

4222 259 62791

Pad holder assy 2-cup

Black

4

4222 247 77141

Spout cover

Black

5

4222 247 77131

Spout

Black

6

4222 247 66481

Drip tray cover

Black

7

4222 247 72531

Drip tray 

8

4222 247 74491

Front cover

Star white

9

4222 247 74501

Housing

Star white

10

4222 259 63611

Brew chamber lid printed

Star white

11

4222 247 74091

Lever

Black

12

4222 247 72881

Pushrod 

13

4222 240 06812

Slider spring 

14

4222 247 35835

Slider 

15

4222 247 07461

Brew chamber seal 

16

4222 259 67751

Distributor assy

Coff ee boost

17

4222 259 59541

3-way valve 

18

4222 259 65481

Boiler assy OPR

230 V

19

4222 247 75271

TCO cap for OPR boiler

20

4222 247 43690

Boiler pin cap 

21

4222 247 72551

Suspension bracket 

22

4222 247 06511

Pressure hose 

23

4222 259 68451

PCB assy OPR/Intensity select

230 V

24

4222 259 68401

Button frame printed

Black

26

4222 259 63422

On/off  button printed 

27

4222 247 72932

Base plate

Black

28

4222 247 05130

O-ring

(NTC)

29

4222 259 39372

NTC assy 

30

4222 247 39963

Sensor housing 

31

4222 259 48665

Water container

Sepia Grey

32

4222 247 40982

Valve outlet

Black

33

4222 259 60151

Back cover assy

Black

34

4222 259 37244

Pump

230 V / 50 Hz

35

4222 247 05191

Pump damper 

36

4213 247 05256

Foot 

100

4222 244 50680

Ty-wrap 

1)

  When you replace the PCB the coff ee volume has to be re-set to your country specifi c 

setting.  Please carry out the Volume Adjustment Procedure to align the volume to your 

local specifi cation  (see table).

Содержание HD6553/10

Страница 1: ...ur setting Star white Functions º Coffee boost technology º Crema improvement º Strength select only for HD6554 HD6555 HD6556 Materials º Housing PP º Housing ABS only for HD6556 º Water container PP º Brew chamber PA º Spout POM º Hoses Silicon º Drip tray Driptray cover PP º Drip tray cover Stainless steel only for some HD6556 º Lever PC º Lever Chrome painted ABS only for some HD6556 Consumer R...

Страница 2: ...sh version 100 ml 69 C 73 C Water specification in mL without coffee pod 1 cup ml with 1 cup pod holder 2 cup ml with 1 cup pod holder General version normal cup 122 ml 133 10 266 10 French Spanish version normal cup 100 ml 109 20 218 20 All countries short cup 60 ml 71 10 142 10 Difference between left right volume 10ml 10ml Functional diagram Boiler Pump 3 way valve Brew head Water Container Ele...

Страница 3: ... back cover and brew chamber becomes visible Put the screwdriver in to the 4 rectangular holes snap locks at the back and gently pull the screwdriver such away that the lips of the snap locks are bent outwards If all clicks positions are loose it is possible to remove the back cover Reassemble follow steps backwards picture 1 picture 2 Removing Brew chamber head handle as follows Disassemble back ...

Страница 4: ...ting the right PCBA modus Enable Disable the Intensity select feature The PCBA is standard delivered with the Intensity select feature disabled this for easy servicing the existing SENSEO Original HD78xx HD6553 range with OPR Boiler installed The Intensity select function can be simple enabled disabled 1 Hold the 2 cups button while applying power to the appliance 2 Release the 2 cups button 3 Pre...

Страница 5: ...sh the one cup button 5 When the appliance has finished you are able to perform the volume adjustment Adjusting the normal 1 cup volume WEU or French Spain 6 Empty the cup podholder and push again for one cup setting measure the volume output with a graduated beaker In the table above you can find the requirements for the minimum maximum water volume output cc ml values 7 Unplug the appliance from...

Страница 6: ... volume is not within specification repeat steps 13 17 18 End Example table switching from WEU to French Spain specification or vice versa you need to execute below Change volume setting Adjusting normal smooth 1 cup volume step 6 12 Adjusting short strong 1 cup volume step 13 17 WEU French Spain Push 7x 1 cups with water in tank 16x 2cups without tank French Spain WEU Push 7x 2 cups with water in...

Страница 7: ...y valve 18 4222 259 65481 Boiler assy OPR 230 V 19 4222 247 75271 TCO cap for OPR boiler 20 4222 247 43690 Boiler pin cap 21 4222 247 72551 Suspension bracket 22 4222 247 06511 Pressure hose 23 4222 259 68451 PCB assy OPR Intensity select 230 V 24 4222 259 68401 Button frame printed Black 26 4222 259 63422 On off button printed 27 4222 247 72932 Base plate Black 28 4222 247 05130 O ring NTC 29 422...

Страница 8: ...HD6553 10 8 10 A 15 12 10 14 13 11 16 6 2 1 4 3 7 8 5 9 Exploded view ...

Страница 9: ...HD6553 10 9 10 36 35 34 31 32 17 18 22 24 23 19 20 30 21 26 27 29 28 33 A Exploded view ...

Страница 10: ...HD6553 10 10 10 Version history 17 07 Version 1 1 HD6553 10 initial release ...