NEW ROYAL 04 OPERATING LOGIC
Saeco International Group
Rev. 00 / July 2011
Page / 07
An NTC is used as a temperature sensor; in the event of overheating this reduces boiler ele
-
ment power consumption.
The electronic system detects the current boiler temperature from the drop in voltage of the
sensor and adjusts it accordingly.
Heating element values and corresponding temperatures
: see table.
4.7. Temperature sensor (adjustment)
Temp. (°C)
R nom (kΩ)
ΔR (+/- %)
20
61.465
8.6
50
17.599
5.9
75
7.214
4.1
80
6.121
3.7
85
5.213
3.4
90
4.459
3.1
100
3.3
2.5
125
1.653
3.9
150
0.893
5.1
4.6. Single microswitch
The gear motor is powered by a direct cur
-
rent motor that engages with the smaller
double toothed wheel using a worm screw.
The unit is mounted on the axle of the large
gear wheel and when a coffee is requested, it
moves from the standby position to the dis
-
pensing position, and then back to the stand-
by position again.
- Standby position: 1
- Dispensing position: 2
2
1
05
Содержание HD 8930
Страница 3: ...Saeco International Group Rev 00 July 2011 NEW ROYAL ...
Страница 8: ...Saeco International Group Rev 00 July 2011 NEW ROYAL ...
Страница 15: ...Saeco International Group Rev 00 July 2011 NEW ROYAL ...
Страница 20: ...Saeco International Group Rev 00 July 2011 NEW ROYAL ...
Страница 28: ...Saeco International Group Rev 00 July 2011 NEW ROYAL ...
Страница 36: ...Saeco International Group Rev 00 July 2011 NEW ROYAL ...
Страница 39: ...Saeco International Group Rev 00 July 2011 NEW ROYAL ...
Страница 49: ...Saeco International Group Rev 00 July 2011 NEW ROYAL ...
Страница 50: ...NEW ROYAL 08 NOTES Saeco International Group Rev 00 July 2011 Page 01 01 ...
Страница 51: ...Saeco International Group Rev 00 July 2011 NEW ROYAL ...
Страница 53: ...Saeco International Group Rev 00 July 2011 NEW ROYAL ...
Страница 54: ...NEW ROYAL 10 WIRING DIAGRAM Saeco International Group Rev 00 July 2011 Page 01 01 ...