![Philips FPF42C128135UA-52 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/philips/fpf42c128135ua-52/fpf42c128135ua-52_service-manual_1548169029.webp)
Circuit Diagrams and PWB Layouts
EN 29
FHP PDP
7.
7.
Circuit Diagrams and PWB Layouts
Not applicable.
8.
Alignments
8.1
Voltage Setting Procedure
On the back of the PDP, in the top right hand corner, you find the Voltage Setting label:
Figure 8-1 Voltage setting label
This Voltage Setting label shows the following messages:
Table 8-1
If the voltage adjustments Vs and Va on the Power Supply Unit must be performed, depends on the version of the Power Supply Unit.
G_16400_034.eps
270706
Item
Adjustment items
Measurement point
Adjustment value (conditions)
1
Vs voltage adjustment
Pins 8-9-10 of CN23 on the X-SUS board
Voltage setting label indication value* ± 1%
2
Va voltage adjustment
Pin 1 of CN23 on the X-SUS board
Voltage setting label indication value* ± 1%