SERVICE MANUAL
LBB 3310/00, 3330/00 and 3331/00
page: 31
Date of issue:
4822 861 11006
July 1998
Delegate microphone permanently off when pressing the priority button at the Chairman unit(s) (RMO)
•
Connect a Delegate and a Chairman unit to the CPSU.
•
Set the Microphone switch of the chairman unit (see Priority button) in position 1.
•
Press the microphone button on the Delegate unit. The light ring illuminates.
•
Press the priority button of the Chairman unit. The light ring goes out.
•
Release the priority button. The microphone and light ring of the Delegate unit stays off.
•
Measure the DC-voltage for each step via M34 related to M8 (0V).
Microphone switch
Priority button
M34
position 1
on
< 0.5V (RMO is inactive)
position 1
off
> 4.0V (RMO is activated)
10.3.8 Priority switch (only for Chairman units)
•
Connect a Chairman unit to the CPSU.
•
Press the Priority button at the Chairman Unit.
•
The Light-ring must illuminate now.
•
A chime tone will now be emitted depending on the position of the chime switch. This switch is accessible by
removing the cable relief bracket (0=no chime at priority, 1=chime at priority).
•
Set the microphone switch (located near the chime switch) successively in position 0 and 1.
•
Keep the Priority button pressed and measure the DC-voltage via M5, related to M2 (GND).
Mode switch
Microphone switch
M5
n.a.
0 = permanent OFF
> 13.35V (RMO activated)
n.a.
1 = temporary OFF
between 8.7V and 10.11V (TRMO- is activated)