SERVICE MANUAL
LBB 3310/00, 3330/00 and 3331/00
page: 14
Date of issue:
4822 861 11006
July 1998
10.2.4 Supply current measurement
Measure the supply current from V+ by means of a current meter in the power supply line itself: this should be between
30mA and 40mA.
K2
X10
1,2,3
V+
3
4,5,6
V-
1
Power Supply
PCB
CPSU
90 ... 264V AC / 24V DC
~
~
A
A1
+
-
003_001.cdr
Figure 1
10.2.5 AUDIO-CONTR to Loudspeaker circuit
Noise level
Measure first the noise, A-weighted & rms, from the loudspeaker-signal between (symmetrical) M57 and M59 (see figure
2):
Noise level (A-weighted): < -70dBV.
6
2
9
5
4
8
2
7
25
Ω
X205 M59
X150
X110
X10
AC
24V DC
Power Supply
90 ... 264V AC
~
~
Loudspeaker
PCB CPSU
M110 M111
M121
M122 M124
M150 M151
M57
(GND)
(GND)
(GND)
003_002.cdr
L
R
IN
Rec-IN
Line-IN
Rec-IN
Telephone
+
-
A1
V
Figure 2