SERVICE MANUAL
LBB 3310/00, 3330/00 and 3331/00
page: 24
Date of issue:
4822 861 11006
July 1998
10.2.10 TELEPHONE-IN to LINE-OUT Circuit
Nominal level, maximum level and bandwidth
25
Ω
X205 M119
X10
AC
24V DC
Power Supply
90 ... 264V AC
~
~
Loudspeaker
PCB CPSU
M2
6
2
9
5
4
8
2
7
X150
X110
M110 M111
M121
M122 M124
M150 M151
(GND)
(GND)
(GND)
Line-OUT
Telephone-IN
Rec-IN
Rec-IN
Line-IN
R
L
GND
+
-
A1
V
-
+
G1
Sine-Wave
Generator
003_012.cdr
X110
5
Figure 12
settings for G1
measurement results for A1
Amplitude
Frequency
Amplification
Nominal level
-14dBV (200mV
rms
)
1kHz
-14dBV +/- 1dB (85dB SPL)
Maximum level
+11dBV (3.55V
rms
)
1 kHz
+11dBV +/- 1dB (110dB SPL)
Bandwidth
-14dBV (200mV
rms
)
125 Hz
-0.5dB +/- 2dB related to nom. level at 1kHz
Bandwidth
-14dBV (200mV
rms
)
12.5 kHz
-0.5dB +/- 1dB related to nom. level at 1kHz.
Содержание CCS 800