6.0 TEST AND INSPECTION PLAN
The test plan is derived from the Product Test Reference of PHILIPS 655.
6.1
User Interface Test
Use the Test SIM Card to test the transceivers as follows :
•
On/Off button
•
LCD Backlight
•
Keyboard Test
•
Side Keys
•
Buzzer Test
•
Vibrator Test
•
Audio Test
•
Antenna Test ( to measure the radiated power level. Not necessary when using an
antenna coupler)
•
LCD
•
IMEI
•
Tester Status/Eeprom Status
With a fast Charger connected with the PRODUCT’s bottom connector, check the full scrolling from one mode to
the next when charging IGN (Ignition) – Battery.
6.2 RF
Test
The purpose of the radio test is to prove that the tested phone is compliant to the Standard.
The radio test must be performed with a
Digital Radio Test Set. The mobile has to
be set on the antenna coupler inside the
shielded chamber.
Due to a not accessible RF connector when the Product is closed, it will be necessary to make radio test inside
Shielded chamber only.
See Help Radio Files Over the antenna - RF Calibration.pdf & Over the antenna - The equipments.pdf under the
Internet Web Site :
http://philipscscc.soft2you.net/
in " Technical Support \ Component List \ Wireless \ PHILIPS 639 " section
Use the Test SIM Card « SP »to test the GSM 900 / DCS 1800 band