8.0 TEST
PROCEDURES
8.1
Initial Functional check for PHILIPS 655
8.1.1 Insert the Test Production Card into the SIM reader at the back of the mobile phone and clip a charged
battery on the phone.
8.1.2 Press the “ON” button for 2 seconds at least and the LCD will show a message, which contains information
of FA (Final Adjustment) status and 12NC.
8.1.3 Follow the instructions as mentioned below:
Step Procedure
Observation
1
Press Key 1
Press Key 1 again.
MANUAL
TEST
GOOD
Left corner displays IDLE STATE
Key 0000
2
Press key 2
Press key 2 again
Camera Test (Allows to check camera
visualisation)
Left corner displays IDLE STATE
Key 0001
3
Press key 3
(Audio loop local effect)
Press key 3 again
"Audio
Test
" Local”
" Audio Section”
“OK”
Left corner displays IDLE STATE
Key 0002
4
Press key 4
Press key 4 again
"LEDS
TEST”
Check keypad Backlight
Left corner displays IDLE STATE
Key 0003
5
Press Key 5
(Checkerboard test) &
Backlight activation
Press Key 5 again
Checkerboard 1, 2 & 3 pixel on
Left corner displays IDLE STATE
Key 0004
6
Press Key 6
Clamshell Test
Press Key 6 again
"MAT CLAM SHELL TEST"
“OPENED”
Close clamshell to test Sub LCD
Checkerboard.
Left corner displays IDLE STATE
Key 0005
7
Press Key 7
Press key 7 again
"KEY WITHOUT TEST"
Left corner displays IDLE STATE
Key 0006
PHILIPS ELECTRONICS N.V. 1999
VY-V-640-P655
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.