Service Modes, Error Codes, and Fault Finding
5.
Figure 5-8 “Active” to “Semi Stand-by” flowchart
19210_077_120504.eps
120504
Semi Standby
Active
Mute all sound outputs according
information in the FMS AUDIO
Mute all video outputs
switch off Ambilight (see CHS ambilight)
Wait 100ms
Wait until Ambilight has faded out:
Output power Observer should be zero
Switch off POK line detection
algorithm (see CHS service)
Shut down the display
(see separate sheet)
Switch Off LCD backlight