Service Modes, Error Codes, and Fault Finding
5.
How to Navigate
•
In the SAM menu, select menu items with the UP/DOWN
keys on the remote control transmitter. The selected item
will be indicated. When not all menu items fit on the screen,
use the UP/DOWN keys to display the next/previous menu
items.
•
With the “LEFT/RIGHT” keys, it is possible to:
–
(De) activate the selected menu item.
–
(De) activate the selected sub menu.
–
Change the value of the selected menu item.
•
When you press the MENU button once while in top level
SAM, the set will switch to the normal user menu (with the
SAM mode still active in the background).
•
Press the following key sequence on the remote control
transmitter: “062596” directly followed by the “Home”
button to switch to SDM (do not allow the display to time out
between entries while keying the sequence).
How to Store SAM Settings
To store the settings changed in SAM mode (except the
RGB Align settings), leave the top level SAM menu by using
the POWER button on the remote control transmitter or the
television set. The mentioned exceptions must be stored
separately via the STORE button.
How to Exit SAM
Use one of the following methods:
•
Switch the set to STANDBY by pressing the mains button
on the remote control transmitter or the television set.
•
Via a standard RC-transmitter, key in “00” sequence.
Note
: When the TV is switched “off” by a power interrupt while
in SAM, the TV will show up in “normal operation mode” as
soon as the power is supplied again. The error buffer will not be
cleared.
Software maintenance
Software events
Display
Display information is for development purposes
Clear
Test reboot
Test cold reboot
Test application crash
Hardware events
Display
Display information is for development purposes
Clear
Test setting
Digital info
Current frequency: 175
QAM modulation: None
Display information is for development purposes
Symbol rate:
Original network ID: 0
Network ID: 0
Transport stream ID: 0
Service ID: 0
Hierarchical modulation: 0
Selected video PID: 16
Selected main audio PID: 16
Selected 2nd audio PID: 16
Install start frequency
000
Install start frequency from “0” MHz
Install end frequency
999
Install end frequency as “999” MHz
Default install frequency
Installation
Digital only
Select Digital only or D Analogue before installation
D Analogue
Development file
versions
Development 1 file version
Display parameters
DISPT5.4.40.24
Display information is for development purposes
Acoustics parameters ACSTS
5.8.6.0
PQ - TV550 5.4.0.9
PQS- Profile set
PQF - Fixed settings
PQU - User styles
Ambilight parameters PRFAM
5.4.15.0
Development 2 file version
12NC one zip software
Display information is for development purposes
Initial main software
NVM version Q554B_0.4.0.0
Flash units software
Temp com file version none
Upload to USB
Channel list
To upload several settings from the TV to an USB stick
Personal settings
Option codes
Alignments
Identification data
History list
All (options included)
Download from USB
Channel list
To download several settings from the USB stick to the TV
Personal settings
Option codes
Alignments
Identification data
All (options included)
NVM editor
Type number
see type plate
NVM editor; re key-in type number and production code
after SSB replacement
AG code
see type plate
Main Menu
Sub-menu 1
Sub-menu 2
Sub-menu 3
Description