Z-Wave Configuration Settings
Notice:
* All of the configuration, the data size is 1.
* The configuration mark with star(*), means after the remove the setting
still keep, don't reset to factory default. Unless the user execute the
“RESET” procedure.
* The reserve bit or not supported bit is allowed any value, but no effect.
NO.
Name
Def.
Valid
A B C
Description
1 Basic Set
OFF Level
0
All
Setting the BASIC command value.
When the flood trigger off(0x00), send
the BASIC CC to the group 2.
2 Basic Set
ON Level
0xFF
All
Setting the BASIC command value.
When the flood trigger on(0xFF), send
the BASIC CC to the group 2.
5
(*)
Operation
Mode
All
0 33 32 Operation mode. Using bit to control.
0
Bit0
: Disable the Flood function.
0
Bit1
: Reserve.
0
Bit2
: Reserve.
0
Bit3
: Setting the temperature scale.
0: Fahrenheit, 1:Celsius
0
Bit4
: Reserve.
0
Bit5
: Disable the temperature report
after event triggered. (1:Disable,
0:Enable)
0
Bit6
: Reserve.
0
Bit7
: Reserve.
6
(*)
Mult-
Sensor
Function
Switch
All
0 64 64
Multisensor function switch. Using bit
to control.
0
Bit0
: Reserve.
0
Bit1
: Reserve.
0
Bit2
: Reserve.
0
Bit3
: Reserve.
6