background image

It could be changed by setting the configuration NO. 10.

Low battery report: When the battery level is too low, every 30

minutes will report once.

Temperature report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 13.

Humidity report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 14.

Flood state report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 15.

Notice

:   The configuration NO. 10, 13, 14 and 15 could be setting to

zero to disable the auto report. And the configuration NO. 20 could

change the tick interval, the default value is 30, if setting to 1, that

means the minimum auto report interval will be one minute. And please

notice if setting this value to zero, that means disable all of the timing

report except the low battery detection.

Power Up Procedure

* Battery Power Check

When the device power up, the device will detect the power level of the

battery immediately. If the power level is too low, the LED will continue

flash about 5 seconds. Please change another new battery.

* NWI

When the device power on, the device will check is it already adding to

the network? If doesn't, it will auto start the NWI mode. The LED will

flash in every second and continue 30 seconds. Until timeout or the

device successful to inclusion by controller.  The use can presses the

tamper key 3 times to abort the NWI mode.

PS:   If   the   device   already   adding   to   the   network,   the   device   will

broadcast a node information once.

* Wake

When the device power on, the device will wake about 20 seconds. In

this duration, the controller can communicate with the device. Normally

the device is always sleeping to save the battery energy.

Over The Air (OTA) Firmware Update

The device support the Z-Wave firmware update via OTA.

Let the controller into the firmware update mode, and then press the

tamper key once to start the update.

After finish the firmware download, the LED will start flash in every 0.5

second. At that time, 

please don't remove the battery

, otherwise it

will cause the firmware broken, and the device will no function.

After the LED stop flash, it is recommended that the user power up the

device.  

Caution

:   After   remove   the   battery,   please   wait   about   30

seconds, and then re-install the battery.

Security Network

The device support the security function. When the device included

with a security controller, the device will auto switch to the security

mode. In the security mode, the follow commands need using Security

CC wrapped to communicate, otherwise it will not response.

COMMAND_CLASS_BATTERY

COMMAND_CLASS_NOTIFICATION_V4

COMMAND_CLASS_ASSOCIATION_V2

COMMAND_CLASS_CONFIGURATION

COMMAND_CLASS_SENSOR_BINARY_V2

COMMAND_CLASS_SENSOR_MULTILEVEL_V5

COMMAND_CLASS_WAKE_UP_V2

4

Содержание PAT02-A

Страница 1: ...The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Function Compare A B C Flood Temperature Humidity PAT02 ...

Страница 2: ...oup 2 is for the light control the device will send the Basic Set command to this group And each group support 8 nodes maximum Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Notice 2 When the device into NWI mode the sensor functionality will useless The NWI mode will timeout a...

Страница 3: ...to disable this function by setting the configuration NO 21 to 0 In the default when the temperature is changed to plus or minus one degree Fahrenheit 0 56 degree Celsius the device will report temperature information to the nodes in the group 1 The device will measure the temperature in every 10 seconds And if the temperature is over 140 degree Fahrenheit 60 degree Celsius the device will always ...

Страница 4: ...seconds Until timeout or the device successful to inclusion by controller The use can presses the tamper key 3 times to abort the NWI mode PS If the device already adding to the network the device will broadcast a node information once Wake When the device power on the device will wake about 20 seconds In this duration the controller can communicate with the device Normally the device is always sl...

Страница 5: ... The way to open the front cover please press the top position to release the cover Replace the new battery and install the cover back 1 Put the front cover bottom and press down 2 Push the front cover top Installation 1 To mount the device on the wall you can choose using the tape or the screw 2 Using the screw to fix the flood detector 5 1 1 2 ...

Страница 6: ... 0x00 send the BASIC CC to the group 2 2 Basic Set ON Level 0xFF All Setting the BASIC command value When the flood trigger on 0xFF send the BASIC CC to the group 2 5 Operation Mode All 0 33 32 Operation mode Using bit to control 0 Bit0 Disable the Flood function 0 Bit1 Reserve 0 Bit2 Reserve 0 Bit3 Setting the temperature scale 0 Fahrenheit 1 Celsius 0 Bit4 Reserve 0 Bit5 Disable the temperature ...

Страница 7: ...emperatur e Time 12 0 127 The interval time for auto report the temperature 0 means turn off auto report The default value is 12 The tick time can setting by the configuration No 20 14 Auto Report Humidity Time 12 0 127 The interval time for auto report the humidity 0 means turn off auto report The default value is 12 The tick time can setting by the configuration No 20 15 Auto Report Flood Time 1...

Страница 8: ... COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 Specifications Power by CR123A lithium battery Signal Frequency 868 40 MHz 869 85 MHz EU 908 40 MHz 916 0...

Страница 9: ... to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modi...

Отзывы: