background image

Adding to Z-Wave

TM

 Network

I

n the front casing, there is an On/Off button with LED indicator which is used to

toggle switch on and off or carry out inclusion, exclusion, reset or association.

When first power is applied, its LED flashes on and off alternately and repeatedly

at 0.5 second intervals. It implies that it has not been assigned a node ID and start

auto inclusion. 

Auto Inclusion

The function of auto inclusion will be executed as long as the switch does not

have Node ID and just plug the switch into a wall outlet.

Note:

 Auto inclusion timeout is 2 minutes; during which the node information of

explorer frame will be emitted once several seconds. Unlike “inclusion” function

as shown in the table below, the execution of auto inclusion is free from pressing

the On/Off button on the Switch.

The table below lists an operation summary of basic Z-Wave functions. Please re-

fer to the instructions for your Z-Wave

TM

  Certificated Primary Controller to ac-

cess the Setup function, and to Add/Remove/Associate devices

Function

Description

Annotation

No node ID

The Z-Wave Controller does not al-

locate a node ID to the Switch.

LED 2-second on, 2-second

off

Add

1. Put your Z-Wave controller into

inclusion mode by following the

instructions   provided   by   the

controller manufacturer.

2.     Pressing   On/Off   button   three

times within 2 seconds will enter

inclusion mode.

Remove

1. Put your Z-Wave controller into

exclusion mode by following the

instructions   provided   by   the

controller manufacturer.

2. Pressing   On/Off   button   three

times within 2 seconds will enter

exclusion mode.

3.Node ID has been excluded.

LED 2s On, 2s Off (Enter

auto inclusion)

Reset

1.

Pressing   On/Off   button   three

times within 2 seconds will enter

inclusion mode.

Use this procedure only in

the   event   that   the   primary

controller   is   lost   or   other-

wise inoperable.

2.

Within   1   second,   press   On/Off

button again for 5 seconds.

3.

IDs are excluded.

LED 2s On, 2s Off (Enter

auto inclusion)

Association

1.

The PAN38 is an always listen-

ing  Z-Wave   device,   so  associa-

tions may be added or removed

by a controller at any time. Or If

your controller requires to have

the   PAN38   send   a   'node   infor-

mation frame or NIF for associa-

tions,   then   pressing   the   On/Off

button three times within 2 sec-

onds   will   cause   the   PAN38   to

send its NIF.

Содержание PAN38

Страница 1: ...to normal status Specification Operating Voltage 100V 240V 50Hz 60Hz Maximum Load Ampere 13A Resistive load PAN38 1 PAN38 2 PAN38 3 Maximum Load Ampere 10A Resistive load PAN38 4 Switzerland Socket Type Germany type PAN38 1 France type PAN38 2 UK type PAN38 3 Switzerland type PAN38 4 Range Minimum 40 m in door 100m outdoor line of sight Operating Temperature 0 C 40 C Frequency Range 868 40MHz 869 ...

Страница 2: ... putting it into use the body of Module will become a little bit hot of which phenomenon is normal Warning 1 Plug out to disconnect from power supply Do not plug in line 2 Do not exceed the max rating Warnung 1 Trennen Sie das Gerät von der Stromzuführung Verwenden Sie das Gerät nicht mit einem DIP Schalter 2 Achten Sie darauf dass die maximale Spannung niemals überschritten wird Warnung für zwisc...

Страница 3: ...ion Annotation No node ID The Z Wave Controller does not al locate a node ID to the Switch LED 2 second on 2 second off Add 1 Put your Z Wave controller into inclusion mode by following the instructions provided by the controller manufacturer 2 Pressing On Off button three times within 2 seconds will enter inclusion mode Remove 1 Put your Z Wave controller into exclusion mode by following the inst...

Страница 4: ...facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Switch is 0 C 40 C 3 Do not locate the Switch where exists combustible substances or any source of heat e g fires radiators boiler etc 4 After putting it into use the body of Switch will become a little bit hot of which phenomenon is normal Installation 1 Plug this On Off Switch into a wall outlet near the load ...

Страница 5: ...Auto report to Grouping 1 Maximum Node 5 2 1 1 On Off Event Report When on or off state has been changed it will send Binary Switch Report to the node of Grouping 1 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5 report When the power consumption of ...

Страница 6: ... Meter Value 4 0xA3 KWh Accumulated power consumption KWh Meter Value 2 65536 Meter Value 3 256 Meter Value 4 800 35 KWh 2 2 3 Clearing accumulated power consumption Whenever re start counting the accumulated power consumption is needed you can use Meter Reset Command to clear it Meter Reset Command Command Class Meter Meter Reset 2 2 4 AC load Voltage V When receiving Meter Get Command it will re...

Страница 7: ...0 99 3 Z Wave s Configuration Configuration Parameter Function Size Byte Value Unit Default Description 1 Watt Meter 2 0x0000 5s 720 0 Disable Watt Report Period 0x7FFF Report 1 32767 5s 45h 2 KWH Meter Report Period 2 0x0000 0x7FFF 10min 6 0 Disable KWh Report 1 32767 10min 227days 3 Threshold of current for Load caution 2 10 1300 0 01A 1300 1300 0 01A 13A 4 Threshold of KWh for Load caution 2 1 ...

Страница 8: ...etting is LAST SWITCH STATE 3 6 Mode of switch off function When the mode of switch On Off is set to 0 any command of switch off will be disabled and the On Off function of include button will be disabled The default setting is enable mode When manual On Off function is disabled the RF com mand can only switch On but not Off This is useful function for keeping the de vice in switch on state 3 7 LE...

Страница 9: ...anted Security Class Meter 5 Highest granted Security Class Multi Channel Association 3 Highest granted Security Class Notification 8 Highest granted Security Class Powerlevel 1 Highest granted Security Class Version 3 Highest granted Security Class Socket Type Since the socket type for each country in Europe varies refer to the outline for each socket suited for each country as follows Germany ty...

Страница 10: ... used in accordance with the instructions may cause harmful inter ference to radio communications However there is no guarantee that interference will not occur in a particular in stallation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encour aged to try to correct the interference by one ...

Отзывы: