Smart energy plug  PAN38

     

This plug-in ON/OFF switch PAN38 is a security enabled wireless switch, based on Z-

Wave Plus technology. Z-Wave Plus

TM

  enabled devices displaying the Z-Wave Plus

TM

logo can also be used with it regardless of the manufacturer, and can also be used in

other manufacturer’s Z-Wave

TM

  enabled networks. Remote On/Off control of the con-

nected load is possible with another manufacturer’s wireless Controller. Each switch is

designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the

signal is received by its intended destination by routing the signal around obstacles and

radio dead spots. Because PAN38 supports Security Command Class, it can learn with

Secured controller. Its functionality and supported command classes are identical when

included as a secure and non-secure device.

This plug-in ON/OFF switch is able to detect instance wattage (3000W/230VAC/13A)

and overload current (14.5A with resistive load) of connected lights or appliances. When

detecting overload state, the Switch will be disabled and it’s On/Off button will be lock-

out of which LED will flash quickly.  However, unplug and reconnect the switch will re-

set its overload condition to normal status.

Specification

Operating Voltage

100V-240V~  50Hz-60Hz

Maximum Load (Ampere)

13A (Resistive load) PAN38-1; PAN38-2; PAN38-3

Maximum Load (Ampere)

10A (Resistive load) PAN38-4 (Switzerland)

Socket Type:

Germany type: PAN38-1

France type: PAN38-2

UK type: PAN38-3

Switzerland type: PAN38-4

Range

Minimum 40 m in door 100m outdoor line of sight

Operating Temperature

0°C ~ 40°C

Frequency Range

868.40MHz & 869.85MHz/ EU (PAN38-1/-2/-3/-4); 

RF Maximum Power

+10dBm (Peak), -10dBm (Average)

 

** Specifications are subject to change and improvement without notice. 

Troubleshooting

 

Symptom

Cause of Failure

Recommendation

The   Switch   not   working

and LED off

1.The   Switch   is   not   plugged   into

the electrical outlet properly

2.The Switch break down

1. Check power connections

2. Don’t open up the Switch

and send it for repair.

The   Switch   LED   illumi-

nating, but cannot control

the Switch of the load at-

tached

1.Check   if   the   load   plugged   into

the   Switch   has   its   own   ON/OFF

switch

2. The switch is protected

1. Set the ON/OFF switch of

the load attached to ON

2. Unprotected the switch or

follow the instruction of pro-

tection.

The   Switch   LED   illumi-

nating,   but  the  Detector

cannot control the Switch

1. Not carry out association

2. Same frequency interference

1. Carry out association

2. Wait for a while to re-try

LED   keep   flashing,   but

cannot control

Overload occurs

Remove the load attached or

check   max.   load   cannot   ex-

ceed 13A (Resistive load)

Содержание PAN38

Страница 1: ...to normal status Specification Operating Voltage 100V 240V 50Hz 60Hz Maximum Load Ampere 13A Resistive load PAN38 1 PAN38 2 PAN38 3 Maximum Load Ampere 10A Resistive load PAN38 4 Switzerland Socket Type Germany type PAN38 1 France type PAN38 2 UK type PAN38 3 Switzerland type PAN38 4 Range Minimum 40 m in door 100m outdoor line of sight Operating Temperature 0 C 40 C Frequency Range 868 40MHz 869 ...

Страница 2: ... putting it into use the body of Module will become a little bit hot of which phenomenon is normal Warning 1 Plug out to disconnect from power supply Do not plug in line 2 Do not exceed the max rating Warnung 1 Trennen Sie das Gerät von der Stromzuführung Verwenden Sie das Gerät nicht mit einem DIP Schalter 2 Achten Sie darauf dass die maximale Spannung niemals überschritten wird Warnung für zwisc...

Страница 3: ...ion Annotation No node ID The Z Wave Controller does not al locate a node ID to the Switch LED 2 second on 2 second off Add 1 Put your Z Wave controller into inclusion mode by following the instructions provided by the controller manufacturer 2 Pressing On Off button three times within 2 seconds will enter inclusion mode Remove 1 Put your Z Wave controller into exclusion mode by following the inst...

Страница 4: ...facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Switch is 0 C 40 C 3 Do not locate the Switch where exists combustible substances or any source of heat e g fires radiators boiler etc 4 After putting it into use the body of Switch will become a little bit hot of which phenomenon is normal Installation 1 Plug this On Off Switch into a wall outlet near the load ...

Страница 5: ...Auto report to Grouping 1 Maximum Node 5 2 1 1 On Off Event Report When on or off state has been changed it will send Binary Switch Report to the node of Grouping 1 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5 report When the power consumption of ...

Страница 6: ... Meter Value 4 0xA3 KWh Accumulated power consumption KWh Meter Value 2 65536 Meter Value 3 256 Meter Value 4 800 35 KWh 2 2 3 Clearing accumulated power consumption Whenever re start counting the accumulated power consumption is needed you can use Meter Reset Command to clear it Meter Reset Command Command Class Meter Meter Reset 2 2 4 AC load Voltage V When receiving Meter Get Command it will re...

Страница 7: ...0 99 3 Z Wave s Configuration Configuration Parameter Function Size Byte Value Unit Default Description 1 Watt Meter 2 0x0000 5s 720 0 Disable Watt Report Period 0x7FFF Report 1 32767 5s 45h 2 KWH Meter Report Period 2 0x0000 0x7FFF 10min 6 0 Disable KWh Report 1 32767 10min 227days 3 Threshold of current for Load caution 2 10 1300 0 01A 1300 1300 0 01A 13A 4 Threshold of KWh for Load caution 2 1 ...

Страница 8: ...etting is LAST SWITCH STATE 3 6 Mode of switch off function When the mode of switch On Off is set to 0 any command of switch off will be disabled and the On Off function of include button will be disabled The default setting is enable mode When manual On Off function is disabled the RF com mand can only switch On but not Off This is useful function for keeping the de vice in switch on state 3 7 LE...

Страница 9: ...anted Security Class Meter 5 Highest granted Security Class Multi Channel Association 3 Highest granted Security Class Notification 8 Highest granted Security Class Powerlevel 1 Highest granted Security Class Version 3 Highest granted Security Class Socket Type Since the socket type for each country in Europe varies refer to the outline for each socket suited for each country as follows Germany ty...

Страница 10: ... used in accordance with the instructions may cause harmful inter ference to radio communications However there is no guarantee that interference will not occur in a particular in stallation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encour aged to try to correct the interference by one ...

Отзывы: