background image

 

In Wall Micro Switch    PAN33

 

                                   

 

Introduction

 

This product can be operated in any Z-Wave network with other Z-Wave certified 

devices from other manufacturers. All mains operated nodes within the network will 

act as repeaters regardless of vendor to increase reliability of the network. Mini size 

design let the module can easily hide itself into the wall box and that will be good 

for the house decoration. 

 

There are many kind of application by using the module to switch Load On and Off, 

one main application is the light control. The new smart relay calibration technology 

can reduce the inrush current caused by the load and let the module work perfectly 

with many kind of light like incandescent, fluorescent and LED light. 

 

 
 

Safety Precautions and Installation 

 

 

 

Avoid installing the unit in storming or raining weather. 

 

 

Be sure to isolate or switch off power source before installing or maintenance. 

 

 

Do ensure that the power supply circuit protected by a 16A circuit breaker or 
suitable equivalent fuse. 

 

 

IMPORTANT

 

 

Installation must be performed by skilled technicians who are informed about 
the standards and technical requirements of the appliance and its proper 
installation. 

 

 

Check your local codes as they apply to your situation. If the house wiring is 
of aluminum, consult with an electrician about proper wiring methods. 

 

Before  proceeding  with  the  installation,  TURN  OFF  THE  POWER  TO  THE 
LIGHTING  CIRCUIT  AT  THE  CIRCUIT  BREAKER  OR  FUSE  BOX  TO  AVOID 
ELECTRICAL SHOCK.

 

 

Specification

 

 

Operating Voltage

 

100 -240VAC 50Hz-60Hz

 

Maximum Load

 

Max. 

6.5A 

(230Vac/120Vac) (Riesistive load)

 

Range

 

Minimum 

40m indoor

 100m outdoor line of sight

 

Operating Temperature

 

0°C 

to

 40°C

 

Humidity

 

Up to 85% max.

 

Storage Temperature

 

-20°C to 60°C

 

Location

 

Indoor use only

 

Frequency Range

 

868.40MHz; 869.85MHz (EU) 

 

908.40MHz; 916.00MHz (USA/Canada) 

 

920.90 MHz, 921.70 MHz, 923.10 MHz (Taiwan)

 

RF Maximum Power

 

+10dBm (Peak), -10dBm (Average) 

 

OTA

 

Support

 

FCC ID

 

RHHPAN33

 

Dimensions

 

47.5 x 39 x15.6 mm

 

Wire

 

0.75mm², 18AWG

 

** Specifications are subject to change and improvement without notice. 

 

 

 
Troubleshooting

 

Symptom

 

Cause of Failure

 

Recommendation

 

The Switch not working and 
LED off

 

1.

 

The Switch is not connect 
to the Main power

 

2.

 

The Switch break down

 

1.

 

Check power connections

 

2. Don’t open up the Switch and 

send it for repair.

 

The Switch LED 

Check if the load connect 

Set the ON/OFF switch of the 

Содержание PAN33

Страница 1: ... informed about the standards and technical requirements of the appliance and its proper installation Check your local codes as they apply to your situation If the house wiring is of aluminum consult with an electrician about proper wiring methods Before proceeding with the installation TURN OFF THE POWER TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL SHOCK Specific...

Страница 2: ...3 Connect external Switch S1 and S2 to L Fig 1 Assembling and wiring For Instruction to http www philio tech com DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Observe national regulations Any works introducing changes into the configuration must be always performed with disconnected voltage Choosing a Suitable Location 1 Do not...

Страница 3: ...be used for inclusion or exclusion for 3 minutes after power up Pressing Include button of PAN33 three times within 2 seconds will enter exclusion mode Node ID has been excluded 2s On 2s Off No node ID Reset Pressing Include button of PAN33 three times within 2 seconds will enter inclusion mode One press one flash Within 1 second press Include button of PAN33 again for 5 seconds IDs are excluded 2...

Страница 4: ... 0xFF both the load attached to the Switch turns on Command Class Basic Basic Set Value 0 0x00 both the load attached to the Switch turns off Command Class Switch Binary Switch Binary Set Value 1 99 255 0xFF both the load attached to the Switch turns on Command Class Switch Binary Switch Binary Set Value 0 0x00 both the load attached to the Switch turns off 1 Z Wave s Groups Association Command Cl...

Страница 5: ...H STATE SWITCH ON The default setting is LAST SWITCH STATE 3 3 Manual On Off Mode The On Off function of S1 S2 and learn switch can be disabled or enabled by this parameter default value is Enable But the learning operation won t be affected When manual On Off function is disabled the RF command can only switch On but not Off This is useful function for keeping the device in switch on state 3 4 LE...

Страница 6: ...ted and found to comply with the limit s for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio ...

Страница 7: ...7 警語 警語 警語 警語 取得審驗證明之低功率射頻器材 非經核准 公司 商號或使用者均不得擅自變更 頻率 加大功率或變更原設計之特性及功能 低功率射頻器材之使用不得影響飛航安全及干擾合法通信 經發現有干擾現象時 應 立即停用 並改善至無干擾時方得繼續使用 前述合法通信 指依電信管理法規定作業之無線電通信 低功率射頻器材須忍受合法 通信或工業 科學及醫療用電波輻射性電機設備之干擾 ...

Отзывы: