background image

 

state

 

2 : Switch on

 

3

 

Manual On/Off

 

mode 

 

1

 

0-1

 

 

 

 

1

 

0

Disable 

 

manual On/Off

 

1

Enable 

 

manual On/Off

 

4

 

LED indication

 

mode

 

1

 

1-3

 

 

1

 

1

Show switch 

 

state

 

2

Show night 

 

mode

 

3 : One flash 

 

mode

 

5

 

Manual Switch

 

Report mode

 

1

 

0-1

 

 

1

 

0 : Disable

 

1 : Enable

 

 

3-1   

External switch mode

 

Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle 

mode, default value is Edge mode.

 

Edge mode: this mode is suitable for the 

bi-stable

 wall switch that has indicator 

point on the switch, and the same position correspond to same state of relay1. If 

the PAN33 relay change the state because of receiving Z-Wave RF command, it 

may need two times of change (switch on to off or switch off to on) to let relay back 

to the correspond state.   

 

Pulse mode: this mode is suitable for the toggle type wall switch to swap the state 

of Relay1.

 

Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every 

time when change the state of the wall switch will also swap the state of Relay1.     

3-2 Restore switch state mode

 

Whenever the AC power return from lost, PAN33 will restore the switch state which 

could be SWITCH OFF

LAST SWITCH STATE

SWITCH ON. The default setting is 

LAST SWITCH STATE.

 

3-3 Manual On/Off Mode

 

The On/Off function of S1

S2 and learn switch can be disabled or enabled by this 

 

parameter, default value is Enable. But the learning operation won’t be affected. 

 

When manual On/Off function is disabled, the RF command can only switch On but 

 

not Off. This is useful function for keeping the device in switch on state.

 

3-4 LED indication Mode:

 

3-4-1 Show switch state

LED on for switch on and off for switch off. The default 

 

 

 

 

 

 

value is Show switch state. 

 

3-4-2 Show night mode

LED off for switch on and on for switch off.

 

3-4-3 One Flash mode

When the state of switch changes, LED will be on only 

 

 

 

 

 

 

one second, then LED keeps off. 

 

3-5 Manual Switch Report mode :

 

      Whenever PAN32 is manually switch on or off, it will send BINARY_SWITCH_ 

 

REPORT to the node of group1. The default setting is Enable the function.

 

 

5.  Firmware update over the air (OTA)

 

PAN33 is based on 700 series SoC and supports Firmware Update Command 

Class, it can receives the updated firmware image sent by controller via the Z-wave 

RF media. It is a helpful and convenient way to improve some function if needed.

 

 

6.  Command Classes

 

The Switch supports Command Classes including…

 

Command Class

 

Version

 

Required Security Class

 

Z-Wave Plus Info

 

2

 

None

 

Security 0

 

1

 

None

 

Security 2

 

1

 

None

 

Содержание PAN33

Страница 1: ... informed about the standards and technical requirements of the appliance and its proper installation Check your local codes as they apply to your situation If the house wiring is of aluminum consult with an electrician about proper wiring methods Before proceeding with the installation TURN OFF THE POWER TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL SHOCK Specific...

Страница 2: ...3 Connect external Switch S1 and S2 to L Fig 1 Assembling and wiring For Instruction to http www philio tech com DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Observe national regulations Any works introducing changes into the configuration must be always performed with disconnected voltage Choosing a Suitable Location 1 Do not...

Страница 3: ...be used for inclusion or exclusion for 3 minutes after power up Pressing Include button of PAN33 three times within 2 seconds will enter exclusion mode Node ID has been excluded 2s On 2s Off No node ID Reset Pressing Include button of PAN33 three times within 2 seconds will enter inclusion mode One press one flash Within 1 second press Include button of PAN33 again for 5 seconds IDs are excluded 2...

Страница 4: ... 0xFF both the load attached to the Switch turns on Command Class Basic Basic Set Value 0 0x00 both the load attached to the Switch turns off Command Class Switch Binary Switch Binary Set Value 1 99 255 0xFF both the load attached to the Switch turns on Command Class Switch Binary Switch Binary Set Value 0 0x00 both the load attached to the Switch turns off 1 Z Wave s Groups Association Command Cl...

Страница 5: ...H STATE SWITCH ON The default setting is LAST SWITCH STATE 3 3 Manual On Off Mode The On Off function of S1 S2 and learn switch can be disabled or enabled by this parameter default value is Enable But the learning operation won t be affected When manual On Off function is disabled the RF command can only switch On but not Off This is useful function for keeping the device in switch on state 3 4 LE...

Страница 6: ...ted and found to comply with the limit s for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio ...

Страница 7: ...7 警語 警語 警語 警語 取得審驗證明之低功率射頻器材 非經核准 公司 商號或使用者均不得擅自變更 頻率 加大功率或變更原設計之特性及功能 低功率射頻器材之使用不得影響飛航安全及干擾合法通信 經發現有干擾現象時 應 立即停用 並改善至無干擾時方得繼續使用 前述合法通信 指依電信管理法規定作業之無線電通信 低功率射頻器材須忍受合法 通信或工業 科學及醫療用電波輻射性電機設備之干擾 ...