4
1. Put the in wall switch into a wall box and connect the AC power wire L, N to
PAN33 connector L, N.
2. Connect the wall switch to the PAN33 as Fig1.
3. There are 3 mode PAN33 can be configured to match different kind of wall
switch, please refer to 3-1
External switch mode
which described in next
section of this user manual
4. If Edge-Toggle mode has been set, and the S1/S2 is connect to normal
bi-stable switch, every time when change the state of the wall switch will also
swap the state of Relay1.
Programming
1. Basic Command Class / Binary Switch Command Class
The Switch will respond to BASIC and BINARY commands that are part of the
Z-Wave system.
1-1 BASIC_GET / BINARY_SWITCH_GET
PAN33 will report ON when relay 1 is ON, or report OFF when relay1 is OFF.
Basic Get Command: [Command Class Basic, Basic Get]
Basic Report Command:
Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]
Report ON:[Command Class Basic, Basic Report, Value = 255(0xFF)]
Binary Switch Get Command:[Command Class Switch Binary, Switch Binary
Get]
Binary Switch Report Command:
Report OFF:[Command Class Switch Binary, Switch Binary Report, Value
=0(0x00)]
Report ON:[Command Class Switch Binary, Switch Binary Report, Value =
255(0xFF)]
1-2 BASIC_SET / SWITCH_BINARY_SET
PAN33 will turn on or off upon receipt of the following commands from a
Z-Wave Controller.
[Command Class Basic, Basic Set, Value = 1~99, 255(0xFF)]: both the load
attached to the Switch turns on.
[Command Class Basic, Basic Set, Value = 0(0x00)]: both the load attached to
the Switch turns off.
[Command Class Switch Binary, Switch Binary Set, Value = 1~99,
255(0xFF)]: both the load attached to the Switch turns on.
[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: both
the load attached to the Switch turns off.
1. Z-Wave’s Groups (Association Command Class Version 2)
The Switch can be set to send reports to the associated Z-Wave devices. It
supports one groups and every group has five nodes support. Group1 is called
Lifeline which support SWITCH_BINARY_REPORT
、
NOTIFICATION_REPORT
、
INDICATOR_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION.
2-1 Auto report to Grouping 1(Maximum Node 5)
2-1-1 On/Off Event Report
When “on” or “off” state has been changed (ex. Press S1 or S2 or include on/off
button), it will send Binary Switch Report to the nodes of Group1.
Binary Switch Report
ON:[Command Class Switch Binary, Switch Binary Report, Value
=255(0xFF)]
OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]
2-1-2 Overload Notification report command
When PAN33 detect the overload, it will send Notification Report to Group1.
The content of Notification Report
Notification report command:[Command Class Notification, Notification
Report, Notification Type = 0x08, Event state = 0x08]
2. Z-Wave’s Configuration
Configura
tion
Paramete
r
Function
Size
(Byte)
Value
Unit
Default
Description
1
External
switch mode
1
1-3
1
1
:
Edge mode
2
:
Pulse mode
3
:
Edge-Toggle
mode
2
Restore switch
state mode
1
0-2
1
0 : Switch off
1 : Last switch