![Philio Technology Corporation PAN10 Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/philio-technology-corporation/pan10/pan10_user-manual_1538013002.webp)
Range
Minimum
40m indoor
, 100m outdoor line of sight
Operating Temperature
0°C to 40°C
Humidity
Up to 85% max.
Storage Temperature
-20°C to 60°C
Location
Indoor use only
Frequency Range
PAN10-1: 868.40MHz; 869.85MHz(EU) /
PAN10-2: 908.40MHz; 916.00MHz(USA/Canada) /
PAN10-3: 920.90 MHz, 921.70 MHz, 923.10 MHz (Taiwan)
PAN10-IL: 916.00MHz(Israel)
RF Power
+5dBm
OTA
support
Dimensions
47.5 x 39 x16 mm
Wire
0.75mm², 18AWG
** Specifications are subject to change and improvement without notice.
Troubleshooting
Symptom
Cause of Failure
Recommendation
The Switch not working and
LED off
1. The Switch is not
plugged into the
electrical outlet
properly
2. The Switch break
down
1. Check power connections
2. Don’t open up the Switch and
send it for repair.
The Switch LED
illuminating, but cannot
1.Check if the load
plugged into the Switch
1. Set the ON/OFF switch of
the
attached
load to ON
control the ON/OFF
Switch of the
attached load
has its own ON/OFF
switch
2. The switch is protected
2. Unprotected the switch or follow
the instruction of protection.
The Switch LED
illuminating, but the
Detector cannot control
the Switch
1. Not carry out
association
2. Same frequency
interference
1. Carry out association
2. Wait for a while to re-try
LED keep flashing, but
cannot control
Overload occurs
Remove the
attached load
or check
max. load cannot exceed
12.0A(Resistive load)
Installation
2