PAN10

Switch Module with meter

   

Introduction

This plug-in ON/OFF switch PAN10 is a security enabled wireless switch, based on 

Z-Wave Plus technology. Z-Wave Plus

TM

 enabled devices displaying the Z-Wave 

Plus

TM

 logo can also be used with it regardless of the manufacturer, and can also be 

used in other manufacturer’s Z-Wave

TM

 enabled networks. Remote On/Off control of 

the connected load is possible with other manufacturer’s wireless Controller. Each 

switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to 

ensure that the signal is received by its intended destination by routing the signal 

around obstacles and radio dead spots. Because PAN10 supports Security 

Command Class, it can learn with Secured controller. Its functionality and supported 

command classes is identical when included as a secure and non-secure device.

This plug-in ON/OFF switch is able to detect instance wattage and overload current 

(12A with resistive load) of connected lights or appliances. When detecting overload 

state, the Switch will be disabled and its On/Off button will be lockout of which LED 

will flash quickly.  However, unplug and re-connect the switch will reset its overload 

condition to normal status.

Safety Precautions and Installation 

Avoid installing the unit in storming or raining weather. 

Be sure to isolate or switch off power source before installing or maintenance. 

Do ensure that the power supply circuit protected by a 16A circuit breaker or 

suitable equivalent fuse. 

IMPORTANT

Installation must be performed by skilled technicians who are informed about 

the standards and technical requirements of the appliance and its proper 

installation. 

Check your local codes as they apply to your situation. If the house wiring is of 

aluminum, consult with an electrician about proper wiring methods. 

Before proceeding with the installation, TURN OFF THE POWER TO THE LIGHTING

CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL 

SHOCK.

Specification

Rated Voltage

100 - 240VAC 50Hz/60Hz 11A

Maximum Load

11A (Resistive load)

1

Содержание PAN10

Страница 1: ...load current 12A with resistive load of connected lights or appliances When detecting overload state the Switch will be disabled and its On Off button will be lockout of which LED will flash quickly However unplug and re connect the switch will reset its overload condition to normal status Safety Precautions and Installation Avoid installing the unit in storming or raining weather Be sure to isola...

Страница 2: ... not plugged into the electrical outlet properly 2 The Switch break down 1 Check power connections 2 Don t open up the Switch and send it for repair The Switch LED illuminating but cannot 1 Check if the load plugged into the Switch 1 Set the ON OFF switch of the attached load to ON control the ON OFF Switch of the attached load has its own ON OFF switch 2 The switch is protected 2 Unprotected the ...

Страница 3: ...ient temperature for the Module is 0 C 40 C 3 Do not locate the Module where exists combustible substances or any source of heat e g fires radiators boiler etc 4 After putting it into use the body of Module will become a little bit hot of which phenomenon is normal Adding to Z WaveTM Network In the front casing there is an On Off button with LED indicator which is used to toggle switch on and off ...

Страница 4: ...g the instructions provided by the controller manufacturer 2 Pressing On Off button three times within 2 seconds will enter inclusion mode Remove Exclusion 1 Put your Z Wave controller into exclusion mode by following the instructions provided by the controller manufacturer 2 Pressing On Off button three times within 2 seconds will enter exclusion mode 3 Node ID has been excluded 0 5s On 0 5s Off ...

Страница 5: ...Overload When overload state occurs the Switch is disabled of which LED flashes on and off alternately at 0 2 second intervals Overload state can be cleared by unplugging and reconnecting the Switch to the wall outlet Installation 1 Put the in wall switch into a wall box and connect the AC power wire L N to PAN10 connector L N 2 Connect the wall switch to the PAN10 as Fig1 Programming 1 Basic Comm...

Страница 6: ... It supports one association group with one node support for Grouping 1 For group 1 the Switch will report its latest status to Z Wave Controller Grouping 1 includes SWITCH_BINARY_REPORT METER_REPORT ALARM_REPORT 2 1 Auto report to Grouping 1 Maximum Node 1 2 1 1 On Off Event Report When on or off state has been changed it will send Binary Switch Report to the node of Grouping 1 Binary Switch Repo...

Страница 7: ...e W Example Meter Value 1 0x00 W Meter Value 2 0x00 W Meter Value 3 0x03 W Meter Value 4 0xEA W Meter W Meter Value 3 256 Meter Value 4 100 2W 2 2 2 Accumulated Power Consumption KWh When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x00 KWh Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Mete...

Страница 8: ... Get Command Command Class Meter Meter Get Scale 0x05 I Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x05 Size 2 Meter Value I Example Scale 0x05 I Precision 2 Size 2 2 Bytes of I Meter Value 1 0x01 I Meter Value 2 0x21 I AC load current Meter Value 1 256 Meter Value 2 2 89 A 2 2 6 load power factor PF When receiving Meter Get Command it wi...

Страница 9: ...de 1 0 4 1 0 Disable 1 5 2 10 3 15 4 20 3 1 Watt Meter Report Period If the setting is configured for 1hour set value 720 the PAN10 will report its instant power consumption every 1 hour to Group1 node The maximum interval to report its instant power consumption is 45 hours 5s 32767 3600 45hr If the setting value is 0 the auto report function of meter Watt will be disabled 3 2 KWH Meter Report Per...

Страница 10: ...and mode Whenever a switch off command BASIC_SET BINARY_SWITCH_SET SWITCH_ALL_OFF is received it could be interpreted as 4 variety of commands 3 9 1 Switch Off It switches to OFF state The default setting is Switch Off 3 9 2 Ignore The switch off command will be ignored 3 9 3 Switch Toggle It switches to the inverse of current state 3 9 4 Switch On It switches to ON state 3 10 Manual Switch Report...

Страница 11: ...LASS_PROTECTION COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 Warning 1 Plug out to disconnect from power supply Do not plug in line 2 Do not exceed the max rating Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote ...

Страница 12: ...he separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the re ceiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must acc...

Отзывы: