Philio Technology Corporation PAN10 Скачать руководство пользователя страница 12

ital device, pursuant to Part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against harmful interfer-

ence in a residential installation. 

This equipment generates, uses and can radiate radio frequency energy and, if not 

installed and used in accordance with the instructions, may cause harmful interfer-

ence to radio communications. 

However, there is no guarantee that interference will not occur in a particular installa-

tion. 

If this equipment does cause harmful interference to radio or television reception, 

which can be determined by turning the equipment off and on, the user is encour-

aged to try to correct the interference by one of the following measures:

 Reorient or relocate the receiving antenna.

 Increase the separation between the equipment and receiver.

 Connect the equipment into an outlet on a circuit different from that to which the re-

ceiver is connected.

 Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject

to the following two conditions:

(1) This device may not cause harmful interference, and

(2) This device must accept any interference received, including interference that 

may cause undesired operation.

FCC Caution: Any changes or modifications not expressly approved by the party re-

sponsible for compliance could void the user's authority to operate this equipment.

This transmitter must not be co-located or operating in conjunction with any other an -

tenna or transmitter.

警語: 

「取得審驗證明之低功率射頻器材,非經核准,公司、商號或使用者均不得擅自變更頻

率、加大功率或變更原設計之特性及功能。

低功率射頻器材之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應

立即停用,並改善至無干擾時方得繼續使用。

前述合法通信,指依電信管理法規定作業之無線電通信。低功率射頻器材須忍受合法通

信或工業、科學及醫療用電波輻射性電機設備之干擾。」

12

Содержание PAN10

Страница 1: ...load current 12A with resistive load of connected lights or appliances When detecting overload state the Switch will be disabled and its On Off button will be lockout of which LED will flash quickly However unplug and re connect the switch will reset its overload condition to normal status Safety Precautions and Installation Avoid installing the unit in storming or raining weather Be sure to isola...

Страница 2: ... not plugged into the electrical outlet properly 2 The Switch break down 1 Check power connections 2 Don t open up the Switch and send it for repair The Switch LED illuminating but cannot 1 Check if the load plugged into the Switch 1 Set the ON OFF switch of the attached load to ON control the ON OFF Switch of the attached load has its own ON OFF switch 2 The switch is protected 2 Unprotected the ...

Страница 3: ...ient temperature for the Module is 0 C 40 C 3 Do not locate the Module where exists combustible substances or any source of heat e g fires radiators boiler etc 4 After putting it into use the body of Module will become a little bit hot of which phenomenon is normal Adding to Z WaveTM Network In the front casing there is an On Off button with LED indicator which is used to toggle switch on and off ...

Страница 4: ...g the instructions provided by the controller manufacturer 2 Pressing On Off button three times within 2 seconds will enter inclusion mode Remove Exclusion 1 Put your Z Wave controller into exclusion mode by following the instructions provided by the controller manufacturer 2 Pressing On Off button three times within 2 seconds will enter exclusion mode 3 Node ID has been excluded 0 5s On 0 5s Off ...

Страница 5: ...Overload When overload state occurs the Switch is disabled of which LED flashes on and off alternately at 0 2 second intervals Overload state can be cleared by unplugging and reconnecting the Switch to the wall outlet Installation 1 Put the in wall switch into a wall box and connect the AC power wire L N to PAN10 connector L N 2 Connect the wall switch to the PAN10 as Fig1 Programming 1 Basic Comm...

Страница 6: ... It supports one association group with one node support for Grouping 1 For group 1 the Switch will report its latest status to Z Wave Controller Grouping 1 includes SWITCH_BINARY_REPORT METER_REPORT ALARM_REPORT 2 1 Auto report to Grouping 1 Maximum Node 1 2 1 1 On Off Event Report When on or off state has been changed it will send Binary Switch Report to the node of Grouping 1 Binary Switch Repo...

Страница 7: ...e W Example Meter Value 1 0x00 W Meter Value 2 0x00 W Meter Value 3 0x03 W Meter Value 4 0xEA W Meter W Meter Value 3 256 Meter Value 4 100 2W 2 2 2 Accumulated Power Consumption KWh When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x00 KWh Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Mete...

Страница 8: ... Get Command Command Class Meter Meter Get Scale 0x05 I Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x05 Size 2 Meter Value I Example Scale 0x05 I Precision 2 Size 2 2 Bytes of I Meter Value 1 0x01 I Meter Value 2 0x21 I AC load current Meter Value 1 256 Meter Value 2 2 89 A 2 2 6 load power factor PF When receiving Meter Get Command it wi...

Страница 9: ...de 1 0 4 1 0 Disable 1 5 2 10 3 15 4 20 3 1 Watt Meter Report Period If the setting is configured for 1hour set value 720 the PAN10 will report its instant power consumption every 1 hour to Group1 node The maximum interval to report its instant power consumption is 45 hours 5s 32767 3600 45hr If the setting value is 0 the auto report function of meter Watt will be disabled 3 2 KWH Meter Report Per...

Страница 10: ...and mode Whenever a switch off command BASIC_SET BINARY_SWITCH_SET SWITCH_ALL_OFF is received it could be interpreted as 4 variety of commands 3 9 1 Switch Off It switches to OFF state The default setting is Switch Off 3 9 2 Ignore The switch off command will be ignored 3 9 3 Switch Toggle It switches to the inverse of current state 3 9 4 Switch On It switches to ON state 3 10 Manual Switch Report...

Страница 11: ...LASS_PROTECTION COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 Warning 1 Plug out to disconnect from power supply Do not plug in line 2 Do not exceed the max rating Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote ...

Страница 12: ...he separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the re ceiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must acc...