208V Single-Phase
120V
120V
208V
L1
L2
GND
NEUTRAL
(NOT USED)
L3 (NOT USED)
CAUTION!
THE 208V IS FED FROM Y-CONNECTION POWER
GRID, AC CHARGER CAN CONNECT TO L1 AND L2, L2
AND L3, L1 AND L3. EARTH GROUND MUST BE
CONNECTED TO NEUTRAL AT ONLY ONE POINT,
USUALLY AT THE BREAKER PANEL.
6.2 Wall-Mounted Installation Requirements
Attach the bracket using fasteners that are appropriate for the type of wall material,
drilling pilot holes if necessary. Use the supplied screws only if mounting the bracket
directly to a wooden stud. If mounting to another type of wall (hollow, masonry, etc.),
use fasteners that are long enough to securely anchor the Wall Connector and can hold
up to 36 kg.
6.3 EVSE Installation Requirements
Choose the Best Location for the Wall Connector Determine the parking location of the
vehicle to ensure that the charge cable reaches the charge port. The Wall Connector
should be located:
●
In an enclosed garage, typically on the vehicle's charge port side.
●
In a well-ventilated area. Avoid installation in an enclosed box, or adjacent to hot
appliances.
●
4 ft (1.2 m) above the floor.
●
8 in (190 mm) from any obstructions to allow for cable looping.
6