Figure 12
Figure 14
STOP
STOP
NATURAL GAS CONVERSION
Natural gas conversion must be performed only by natural gas provider or a service company.
1. Disconnect the propane hose from the gas valve (see Figure 12).
Caution: The propane tank shall be shut off prior to disconnecting the propane hose, before proceeding with the conversion.
inlet tube
bellows
natural gas orifice
gas valve
propane hose
2. Unscrew and disconnect the propane orifice from the bellows (see Figure 13). Propane orifice (2.21 mm diameter size) is painted
with red mark.
3. Replace the propane orifice withs the natural gas orifice and screw the natural gas orifice to the bellows tightly. Then connect and
tighten the natural gas orifice to the inlet tube (see Figure 14). The Natural gas orifice (4.18 mm diameter size ) is painted with a
black mark.
11
NATURAL GAS CONVERSION
Figure 13
propane orifice
bellows
propane orifice
bellows
LIFE GETS BETTER WITH PHI VILLA