gas valve / regulator hose connection (Figure 22)
inlet tube / bellows connection (Figure 23)
gas control knob
ignition button
OFF (APG.)
MAX
(MÁX.)
1 AAA
1.5V
IGNITOR
( Encendedor )
ON/MIN
(ENC./MÍN.)
LIGHTING INSTRUCTIONS
1. Push in gas control knob slightly and
2. Turn gas control knob to “ON/MIN”.
3. Push in gas control knob all the way
4. If the burner does not light in 15
1. Push in gas control knob slightly and turn to “OFF”.
TO TURN OFF GAS
INSTRUCCIONES DE ENCENDIDO
PARA CERRAR EL GAS
1. Presione ligeramente la perilla de control del gas y gírela a la
2. Gire la perilla de control del gas a “ENC/MÍN” (encendido/mínimo).
3. Presione la perilla de control del gas hasta el fondo y mantenga presionada.
4. Si el quemador no se enciende en 15 segundos, suelte la perilla y esta
encender el quemador nuevamente, repita los pasos 1 al 3.
1. Presione ligeramente la perilla de control del gas y gírela a la
turn to “OFF”.
and hold. Continue to press the
ignition button for 15 seconds.
seconds, release the knob and it will
pop back out. Wait 5 minutes before attempting
to light the burner again, repeat step 1 to 3.
posición “APG” (apagado).
Siga presionando el botón de encendido durante 15 segundos.
volverá a su posición hacia afuera. Espere 5 minutos antes de intentar
posición “APG” (apagado)
Lighting Instructions
1. Make 2~3 oz. of leak solution by mixing one part liquid dishwasher detergent and three parts water. Noted: make sure control knob
is “OFF”.
2. Apply several drops of solution where the cylinder attaches to regulator, (see Figure 19), inspect the solution at the connection
looking for bubbles. If NO bubbles appear, the connection is secure. If bubbles appear, the connection has the leak, disconnect the
regulator, reconnect, perform another leak check. If you continue to see bubbles after several attempts, cylinder valve is defective
and should be returned to cylinder’s supplier.
3. Apply several drops of solution where natural gas fixture attaches to natural gas supply system connection (see Figure 20), If NO
bubbles appear, the connections are secure. If bubbles appear, the connection has the leak, disconnect, reconnect, perform another
leak check. If you continue to see bubbles after several attempts, the conversion hose is defective and should replace with a new one.
4. Apply several drops of solution where gas valve attaches to bellows, (see Figure 21), where gas valve attaches to regulator hose,
(see Figure 22), and where inlet tube attaches to bellows, (see Figure 23). If NO bubbles appear, the connections are secure. If bubbles
appear, the connection has the leak, disconnect, reconnect, perform another leak check. If you continue to see bubbles after several
attempts, both parts are defective and should replace with the new ones.
1. Push in gas control knob slightly and turn to “OFF”.
2. Turn gas control knob to “ON/MIN”.
3. Push in gas control knob all the way and hold. Continue to press the ignition button for 15 seconds.
4. If the burner does not light in 15 seconds, release the knob and it will pop back out. Wait 5 minutes before attempting to light the
burner again and repeat step 1 to 3.
To turn off gas
1. Push in gas control knob slightly and turn to “OFF”.
To perform a leak test:
Figure 24
OPERATION INSTRUCTIONS
WARNING:
For your safety, read and follow the Lighting Instructions in this manual and in the Rating Plate on
the appliance. IMPROPER LIGHTING PROCEDURES COULD RESULT IN A FIRE HAZARD OR EXPLOSION
HAZARD OR PROPERTY DAMAGE, INJURY OR LOSS OF LIFE.
14
LIFE GETS BETTER WITH PHI VILLA