background image

Phason 

Optional communication line protection 

25048008 

 

Converter loopback connector 

The Converter loopback connector is for testing the  

RS-485 Converters for PCH channels. 

 

Daisy-chain loopback connector 

The daisy-chain loopback connector is for testing 
individual connections at the devices on the 

communication channel. For devices with a five or 
six-position male connector, the 

A B C D

 pins of the 

connector must line up as shown in the diagram. 

 

Optional communication line protection 

Phason's Data Surge Suppressor (model 

DSS

) protects four-wire, dual-pair communication lines 

from temporary high-voltage conditions caused by electrical interference, power surges, and 
lightning strikes.  

Transient voltages, also known as surges or spikes, can travel through low-voltage data-signal lines 
(communication lines) and cause damage to equipment. Transient voltage surge suppression can 

greatly improve communication signal quality and increase the life of controls and other electronic 
equipment. 

 

Features  

 

Three-stage lightning and transient protection 
for low-voltage data-signal lines 

 

Fault current protection 

 

Resettable solid-state fuses 

 

Fast response time 

 

Emergency bypass connection 

 

Rugged enclosure (corrosion resistant, water 
resistant, and fire retardant) 

 

Limited warranty (90 days) 

 

For additional information about the Data Surge Suppressor, visi

www.phason.ca

. 

Содержание RS485-FD

Страница 1: ...the Phason software on your computer to communicate with the devices along a communication channel A communication channel is a continuous line of cable connecting all devices in the series in other...

Страница 2: ...computer 3 Installing the software drivers on the computer Communication cable requirements The following types of cable are acceptable Phason does not recommend other types of wire Unshielded twiste...

Страница 3: ...gory 5 CAT5 You can use either unshielded twisted pair UTP or shielded twisted pair STP cable Phason does not recommend other types of wire There are additional guidelines to follow when using STP cab...

Страница 4: ...other models must be removed using wire cutters For more information about the location of termination resistors see the installation guide for your specific product If you remove the termination resi...

Страница 5: ...f wire to connect to a reference point on the circuit board in place of the E terminal For information about which terminal to use in place of the E terminal see the user manual for the specific devic...

Страница 6: ...m the USB stick 5 When installation has finished connect the RS485 FD to one of your computer s USB ports To manually start driver installation open My Computer or Windows Explorer Browse the USB stic...

Страница 7: ...from temporary high voltage conditions caused by electrical interference power surges and lightning strikes Transient voltages also known as surges or spikes can travel through low voltage data signa...

Страница 8: ...Phone 204 233 1400 Fax 204 233 3252 Phason Inc 2 Terracon Place Winnipeg Manitoba Canada R2J 4G7 E mail support phason ca Web site www phason ca...

Отзывы: