Measures to be taken in the event of a water supply failure
Using the strainer incl. filter screen (item no. 00 00 69 06) and booster pump, supply the machine with clean
water from a container.
Measures to be taken if there is a risk of frost
After cleaning the machine:
Disconnect water supply.
Remove mixing shaft.
Open the water bleeder valve (1) and relieve the water pressure in the hose.
Disconnect the water hose and empty it.
Open the outlet tap (2) on the water manifold.
Remove water hose from the spraying gun and attach it to the water inlet.
Switch on the main switch.
Switch on compressor (insert plug).
Press the water flow button. The water is now blown out of the manifold with
compressed air (at 1.5 bar for approx. 1 minute).