Position “0”
The star wheel is switched off, thus interrupting the material supply to the mixing area,
for example when cleaning the mixing area with a mixing cleaner or when adjusting
the pump.
Connect the mortar pressure gauge to the pressure flange.
Fill the storage container with dry mortar.
Turn the star wheel switch (1) to “1”. Insert the dummy plug (2). Now the machine is
running. The mortar consistency can now be checked at the mortar outlet flange (do not
connect the mortar hose yet). Set the water quantity to approx. 10% above the nominal
value with the motor running. The reference value is the water setting for the correct
mortar consistency;
e.g. Knauf MP 75 – reference value approx. 650 to 750 l/h.
If mortar emerges, correct the water supply for optimum consistency by adjusting the
water quantity with the needle valve – visible on the cone of the water flow meter.
Turn the hand wheel in a clockwise direction to reduce water flow. Turn it in the
opposite direction to increase water flow.
Press the red “OFF” pushbutton (machine stops)
Connect the air hose to the air manifold and spraying gun
Switch on compressor (insert plug)